Related Experiment Video
Updated: Mar 6, 2026

Thermal Ablation for the Treatment of Abdominal Tumors
Published on: March 7, 2011
Multipoint temperature monitoring in liver undergoing computed tomography-guided radiofrequency ablation with fiber
Abstract:
In this work, we investigated the temperature increment experienced by biological tissue during radiofrequency ablation (RFA). The measurements were performed by using two custom-made thermal probes based on fiber optic sensors (fiber Bragg gratings, FBGs). The two probes embed a total of 9 FBGs. Experiments were performed during RFA of an ex vivo healthy porcine liver. The RFA heating module was equipped with 5 thermocouples. Results show that the temperature increment close to the applicator (i.e., 0.6 cm-0.7 cm) reaches the temperature which is set as a target on the RFA module (i.e., approximately 100 °C). The distance from the applicator also has an impact on the dynamics of the heating phenomenon: at short distances the tissue temperature reaches a steady state condition after a few minutes, on the other hand the sensors placed at a distance ≥2cm did not reach the steady-state conditions during the 14-minute procedure. The multipoint temperature monitoring, which uses sensors at several distances from the applicator, can provide useful information regarding the boundary of damaged volume. This approach can be combined with the monitoring temperature system embedded in the heating equipment, to better control the damaged volume, and to improve the treatment outcomes.
More Related Videos
06:25Cooling or Warming the Esophagus to Reduce Esophageal Injury During Left Atrial Ablation in the Treatment of Atrial Fibrillation
Published on: March 15, 2020
05:43Author Spotlight: Improving Lesion Contiguity in Pulmonary Vein Isolation via Proactive Esophageal Cooling
Published on: April 19, 2024
Related Concept Videos
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Ultrasound II: Endoscopic Ultrasound and FibroScan
Endoscopic Ultrasound (EUS):