Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Pulse rhythm01:30

Pulse rhythm

1.5K
Pulse rhythm refers to the pattern of pulsations within specific intervals, offering valuable insights into the regularity or irregularity of the heart's beats as observed through the pattern of pulsation within specific intervals. A regular pulse exhibits a consistent heart rate with uniform waveforms and pulsation force, variations of which can be classified as normal, weak, or bounding.
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
1.5K
Assessing Blood pressure using a doppler ultrasound01:19

Assessing Blood pressure using a doppler ultrasound

2.7K
To obtain accurate blood pressure measurements in clinical settings, especially when traditional methods are insufficient, healthcare professionals utilize the Doppler ultrasound technique. This method uses high-frequency sound waves to detect blood flow within the arteries, which is crucial for patients with conditions that complicate circulatory system assessment.
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
2.7K
Doppler Effect - II01:05

Doppler Effect - II

5.0K
The Doppler effect has several practical, real-world applications. For instance, meteorologists use Doppler radars to interpret weather events based on the Doppler effect. Typically, a transmitter emits radio waves at a specific frequency toward the sky from a weather station. The radio waves bounce off the clouds and precipitation and travel back to the weather station. The radio frequency of the waves reflected back to the station appears to decrease if the clouds or precipitation are moving...
5.0K
Equipments Used To Measure Blood Pressure01:30

Equipments Used To Measure Blood Pressure

3.8K
Direct Method
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
3.8K
Holter Monitor: 24-Hour Monitoring01:23

Holter Monitor: 24-Hour Monitoring

3.5K
Holter monitoring is a continuous electrocardiography (ECG) recording that tracks the heart's electrical activity over an extended period, generally 24 to 48 hours. This noninvasive diagnostic tool detects irregular heart rhythms that may not be captured during a standard ECG performed in a clinical setting.DeviceThe Holter monitor is a portable, small device connected to several electrodes on the patient's chest. These electrodes detect the heart's electrical signals and transmit them to the...
3.5K
Factors Influencing Heart Rate01:30

Factors Influencing Heart Rate

7.1K
The heart rate, or pulse rate, is a vital indicator of cardiovascular health. It reflects the number of times the heart beats per minute. Various physiological and environmental factors influence heart rate, increasing or decreasing cardiac output. Understanding these factors is crucial for assessing heart function and identifying potential health issues.
Let us explore the significant factors affecting heart rate, including age, body temperature, posture, acute pain, chemical influences,...
7.1K

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Medical Image Registration with Multi-Dilated Convolution and Quintuple Attention.

Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference·2025
Same author

AdaptiveEdge: Adaptive Model Update for Motor-Intent Decoding With Knowledge Distillation and Efficient EMG Sensor System.

IEEE transactions on neural systems and rehabilitation engineering : a publication of the IEEE Engineering in Medicine and Biology Society·2025
Same author

D2C-Morph: Brain regional segmentation based on unsupervised registration network with similarity analysis.

Computerized medical imaging and graphics : the official journal of the Computerized Medical Imaging Society·2025
Same author

Prolonging exciton lifetime of WSe<sub>2</sub> monolayer through image dipole interaction leading to huge enhancement of photocurrent.

Nanophotonics (Berlin, Germany)·2024
Same author

CytoNet: an efficient dual attention based automatic prediction of cancer sub types in cytology studies.

Scientific reports·2024
Same author

Resting-state frontal electroencephalography (EEG) biomarkers for detecting the severity of chronic neuropathic pain.

Scientific reports·2024

Related Experiment Video

Updated: Mar 6, 2026

Real-Time Electrocardiogram Monitoring During Treadmill Training in Mice
04:45

Real-Time Electrocardiogram Monitoring During Treadmill Training in Mice

Published on: May 5, 2022

3.1K

Tracking driver's heart rate by continuous-wave Doppler radar.

Kwang Jin Lee, Chanki Park, Boreom Lee

    Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference
    |March 9, 2017
    PubMed
    Summary

    This study introduces a new non-contact method using Multiple Signal Classification (MUSIC) to accurately estimate a driver's heart rate (HR) from radar signals, even with motion artifacts.

    More Related Videos

    Ultrasound-based Pulse Wave Velocity Evaluation in Mice
    08:07

    Ultrasound-based Pulse Wave Velocity Evaluation in Mice

    Published on: February 14, 2017

    14.6K
    Continuous Venous-Arterial Doppler Ultrasound During a Preload Challenge
    09:32

    Continuous Venous-Arterial Doppler Ultrasound During a Preload Challenge

    Published on: January 20, 2023

    4.2K

    Related Experiment Videos

    Last Updated: Mar 6, 2026

    Real-Time Electrocardiogram Monitoring During Treadmill Training in Mice
    04:45

    Real-Time Electrocardiogram Monitoring During Treadmill Training in Mice

    Published on: May 5, 2022

    3.1K
    Ultrasound-based Pulse Wave Velocity Evaluation in Mice
    08:07

    Ultrasound-based Pulse Wave Velocity Evaluation in Mice

    Published on: February 14, 2017

    14.6K
    Continuous Venous-Arterial Doppler Ultrasound During a Preload Challenge
    09:32

    Continuous Venous-Arterial Doppler Ultrasound During a Preload Challenge

    Published on: January 20, 2023

    4.2K

    Area of Science:

    • Biomedical Engineering
    • Automotive Safety Systems
    • Signal Processing

    Background:

    • Driving safety systems increasingly incorporate medical assistance devices to prevent accidents.
    • Current heart rate (HR) monitoring often requires direct sensor contact (e.g., ECG, PPG).
    • Non-contact HR monitoring using continuous-wave Doppler radar is an emerging area, but susceptible to motion artifacts.

    Purpose of the Study:

    • To develop and evaluate a novel non-contact method for accurate driver heart rate estimation.
    • To address the limitations of existing methods in the presence of motion artifacts.
    • To improve the reliability of radar-based physiological monitoring for automotive applications.

    Main Methods:

    • Utilized continuous-wave Doppler radar for non-contact heart rate (HR) monitoring.
    • Proposed and implemented the Multiple Signal Classification (MUSIC) algorithm for HR estimation.
    • Compared the performance of MUSIC against the Fast Fourier Transform (FFT) method using real driving data.

    Main Results:

    • The MUSIC algorithm demonstrated superior accuracy in estimating HR from radar Doppler signals compared to FFT.
    • The proposed method effectively mitigated the impact of motion artifacts on HR estimation.
    • Accurate HR estimation was achieved even under conditions with significant driver movement and vehicle vibration.

    Conclusions:

    • Multiple Signal Classification (MUSIC) offers a robust and accurate solution for non-contact driver heart rate monitoring.
    • This technique overcomes the limitations of traditional FFT methods when dealing with motion artifacts in radar signals.
    • The developed method holds significant potential for enhancing driver safety systems through reliable, non-invasive physiological monitoring.