A wrist worn SpO2 monitor with custom finger probe for motion artifact removal
Abstract:
Continuous monitoring of blood oxygen saturation (SpO2) level and heart rate is critical in surgery, ICUs and patients suffering from Chronic Obstructive Pulmonary Diseases. Pulse oximeters which compute SpO2 using transmittance photoplethysmography (PPG), is widely accepted for continuous monitoring. Presence of motion artifacts in PPG signals is a major obstacle in the extraction of reliable cardiovascular parameters, in real time and continuous monitoring applications. In this paper, a wrist worn device with a custom finger probe with an integrated accelerometer to remove motion artifacts is presented. An algorithm which can run on low power systems with processing constraints is implemented on the device. The device does continuous acquisition of PPG and accelerometer waveforms and computes SpO2 using the proposed light weight algorithm. The measurement results are continuously synced with an Android tablet, which acts as a gateway and is pushed on to the cloud for further analysis. The accuracy in SpO2 measured by the device was validated using Fluke ProSim 8 SpO2 simulator and the efficiency in accurately computing SpO2 in the presence of motion was validated over 40 healthy volunteers in a controlled setting.
Related Concept Videos
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessment of radial pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps:
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation