Irradiator Commissioning and Dosimetry for Assessment of LQ α and β Parameters, Radiation Dosing Schema, and in vivo Dose Deposition
Published on: March 11, 2021
Quantitative evaluation by measurement and modeling of the variations in dose distributions deposited in mobile
Imad Ali1, Nesreen Alsbou2, Jean-Michel Taguenang3
1Department of Radiation Oncology, University of Oklahoma Health Sciences Center, Oklahoma City, OK, USA.
Abstract:
The objective of this study is to quantitatively evaluate variations of dose distributions deposited in mobile target by measurement and modeling. The effects of variation in dose distribution induced by motion on tumor dose coverage and sparing of normal tissues were investigated quantitatively. The dose distributions with motion artifacts were modeled considering different motion patterns that include (a) motion with constant speed and (b) sinusoidal motion. The model predictions of the dose distributions with motion artifacts were verified with measurement where the dose distributions from various plans that included three-dimensional conformal and intensity-modulated fields were measured with a multiple-diode-array detector (MapCheck2), which was mounted on a mobile platform that moves with adjustable motion parameters. For each plan, the dose distributions were then measured with MapCHECK2 using different motion amplitudes from 0-25 mm. In addition, mathematical modeling was developed to predict the variations in the dose distributions and their dependence on the motion parameters that included amplitude, frequency and phase for sinusoidal motions. The dose distributions varied with motion and depended on the motion pattern particularly the sinusoidal motion, which spread out along the direction of motion. Study results showed that in the dose region between isocenter and the 50% isodose line, the dose profile decreased with increase of the motion amplitude. As the range of motion became larger than the field length along the direction of motion, the dose profiles changes overall including the central axis dose and 50% isodose line. If the total dose was delivered over a time much longer than the periodic time of motion, variations in motion frequency and phase do not affect the dose profiles. As a result, the motion dose modeling developed in this study provided quantitative characterization of variation in the dose distributions induced by motion, which can be employed in radiation therapy to quantitatively determine the margins needed for treatment planning considering dose spillage to normal tissue.
More Related Videos
Related Concept Videos
Model Approaches for Pharmacokinetic Data: Distributed Parameter Models
The distributed parameter models are specifically designed to account for variations and differences in some drug classes. This model is particularly useful for assessing regional concentrations of anticancer or...
Pharmacokinetic Models: Comparison and Selection Criterion
Physiological models take a detailed approach by considering specific molecular processes. They can predict drug distribution, metabolism, and elimination changes, providing a comprehensive understanding of how drugs interact with the body.
Dose Size and Dosing Frequency: Determination Methods
Biological Effects of Radiation
Measurement of Bioavailability: Pharmacodynamic Methods
Pharmacodynamic Models: Linear Concentration–Effect Model