Related Experiment Video
Updated: Mar 6, 2026

05:21
Laparoscopic Extracorporeal Knot-Tying for Uterine Vessel Occlusion during Hysterectomy with Cervical Cerclage in Large Uteri
Published on: September 12, 2025
632
Comparing two Uterine Manipulators During Total Laparoscopic Hysterectomy: A Randomized Controlled Trial
Heinrich Husslein1, Helena Frecker2, Eliane M Shore2
1Department of Obstetrics and Gynecology, Vienna General Hospital, Medical University of Vienna, Austria.
Journal of Minimally Invasive Gynecology
|March 11, 2017
Summary
The Hohl manipulator significantly reduced operative time during total laparoscopic hysterectomy (TLH) compared to the Colpo-Probe. However, this did not lead to less thermal damage to the vaginal cuff, indicating a need for further research.
Area of Science:
- Gynecologic Surgery
- Minimally Invasive Procedures
- Surgical Instrumentation
Background:
- Total laparoscopic hysterectomy (TLH) is a common gynecologic procedure.
- Uterine manipulators are essential tools in TLH, aiding in visualization and surgical access.
- Different types of uterine manipulators exist, with varying designs potentially impacting surgical outcomes.
Purpose of the Study:
- To compare the efficacy and safety of two uterine manipulators: the tight-fitting Colpo-Probe Vaginal Fornix Delineator and the loose-fitting Hohl manipulator.
- To evaluate operative times, specifically colpotomy duration and time from skin incision to uterine detachment.
- To assess the extent of thermal damage to the vaginal cuff associated with each manipulator.
Main Methods:
- A randomized controlled trial was conducted involving women undergoing TLH.
- Patients were randomly assigned to use either the Colpo-Probe or the Hohl manipulator.
- Primary endpoints included time for colpotomy, time from skin incision to uterine detachment, and histologic assessment of vaginal thermal damage.
Main Results:
- Ninety-one patients were analyzed; 49 in the Hohl group and 42 in the Colpo-Probe group.
- The Hohl manipulator group demonstrated significantly shorter median times for manipulator insertion, skin incision to uterine detachment, and colpotomy.
- No significant difference was found in the median maximum thermal damage to the vagina between the two groups.
Conclusions:
- The Hohl manipulator is associated with reduced operative time during TLH.
- Shorter colpotomy times with the Hohl manipulator did not correlate with decreased thermal damage to the vaginal cuff.
- Further comparative studies are needed to identify optimal uterine manipulators for surgical efficiency and minimized thermal spread.