Related Experiment Video
Updated: Mar 6, 2026

The Role of Indocyanine Green Fluorescence in Complex Laparoscopic Cholecystectomy Navigation
Published on: January 31, 2025
ICG fluorescence imaging for quantitative evaluation of colonic perfusion in laparoscopic colorectal surgery
Toshiaki Wada1, Kenji Kawada2, Ryo Takahashi1
1Department of Surgery, Graduate School of Medicine, Kyoto University, 54 Shogoin- Kawara-cho, Sakyo-ku, Kyoto, 606-8507, Japan.
Background:
Fluorescence technology with indocyanine green (ICG) provides a real-time assessment of intestinal perfusion. However, a subjective evaluation of fluorescence intensity based on the surgeon's visual judgement is a major limitation. This study evaluated the quantitative assessment of ICG fluorescence imaging in determining the transection line of the proximal colon during laparoscopic colorectal surgery.
Methods:
This is a retrospective analysis of a prospectively maintained database of 112 patients who underwent laparoscopic surgery for left-sided colorectal cancers. After distal transection of the bowel, the specimen was extracted extracorporeally and then the proximal colon was divided within the well-perfused area based on the ICG fluorescence imaging. We evaluated whether quantitative assessment of intestinal perfusion by measuring ICG intensity could predict postoperative outcomes: F max, T max, T 1/2, and Slope were calculated.
Results:
Anastomotic leakage (AL) occurred in 5 cases (4.5%). Based on the fluorescence imaging, the surgical team opted for further proximal change of the transection line up to an "adequate" fluorescent portion in 18 cases (16.1%). Among the 18 patients, AL occurred in 4 patients (4/18: 22.2%), whereas it occurred in only 1 case (1/94: 1.0%) in the good perfusion patients who did not need proximal change of the transection line. The F max of the AL group was less than 52.0 in all 5 cases (5/5), whereas that of the non-AL group was in only 8 cases (8/107): with an F max cutoff value of 52.0, the sensitivity and specificity for the prediction of AL were 100 and 92.5%, respectively. Regarding postoperative bowel movement recovery, the T max of the early flatus group or early defecation group was significantly lower than that of the late flatus group or late defecation group, respectively.
Conclusions:
ICG fluorescence imaging is useful for assessing anastomotic perfusion in colorectal surgery, which can result in more precise operative decisions tailored for an individual patient.
More Related Videos
14:56Application of Indocyanine Green Fluorescence Imaging Technology in Laparoscopic Duodenum-Preserving Pancreatic Head Resection
Published on: November 21, 2025
05:27Laparoscopic Anatomical Hepatectomy Using Takasaki's Approach and Indocyanine Green Fluorescence Navigation
Published on: May 16, 2025