Objective:
Adequate maintenance of hypnosis during anesthesia throughout surgery using sevoflurane alone was investigated. In addition, sevoflurane pharmacokinetics during cardiopulmonary bypass were analyzed.
Design:
This was a pilot pharmacokinetic study.
Setting:
Tertiary care university hospital.
Participants:
The study comprised 10 patients aged between 18 and 75 years who underwent elective mitral valve surgery.
Interventions:
The end-tidal and sevoflurane plasma concentrations were measured throughout cardiac surgery procedures involving cardiopulmonary bypass. The sevoflurane plasma concentration was measured using gas chromatography. In addition, the ratio between sevoflurane alveolar concentration and inspired concentration over time (FA/FI) was analyzed to describe wash-in and wash-out curves.
Measurements And Main Results:
Hypnosis was maintained adequately throughout surgery using sevoflurane alone. The bispectral index was maintained between 40 and 60 during cardiopulmonary bypass. The end-tidal sevoflurane was significantly different before and during cardiopulmonary bypass (1.86%±0.54% v 1.30%±0.58%, respectively; p<0.001). However, the sevoflurane plasma concentration was not significantly different before and after cardiopulmonary bypass start-up (40.55 µg/mL [76.62-125.33] before cardiopulmonary bypass and 36.24 µg/mL [56.49-81-42] during cardiopulmonary bypass). This mismatch possibly can be explained by changes that occured after cardiopulmonary bypass start-up, such as reductions of body temperature (36.33°C±0.46°C v 32.98°C±2.38°C, respectively; p<0.001) and hematocrit (35.62%±3.98% v 25.5%±3.08%, respectively; p<0.001). The sevoflurane alveolar concentration varied according to sevoflurane plasma concentration and bispectral index values. No adverse events regarding sevoflurane administration during cardiopulmonary bypass were observed.
Conclusions:
Sevoflurane end-tidal values were reliable indicators of adequate anesthesia during all cardiac surgery procedures involving cardiopulmonary bypass.
More Related Videos
05:39Author Spotlight: A Non-Intubated Video-Assisted Thoracoscopic Surgery with Multimodal Analgesia and Sevoflurane Inhalation Anesthesia
Published on: May 26, 2023
04:56In Vitro Method to Control Concentrations of Halogenated Gases in Cultured Alveolar Epithelial Cells
Published on: October 23, 2018
Related Concept Videos
Cardiomyopathy VII: Pre and Post Operative Nursing Management
Inhalational Anesthetics: Overview
General Anesthesia: Overview
General anesthesia induces unconsciousness in the whole body, while the others target specific areas or sensations. It is administered to minimize adverse effects, maintain...
Parenteral Anesthetics: Overview
Stages of General Anesthesia
Cardiopulmonary Resuscitation II: ACLS Airway Management