Related Experiment Video
Updated: Mar 6, 2026

Treatment of Ankle Osteoarthritis with Total Ankle Replacement Through a Lateral Transfibular Approach
Published on: January 24, 2018
Comparison between Simple Radiographic and Computed Tomographic Three-Dimensional Reconstruction for Evaluation of
Eduardo Pedrini Cruz1, Felipe Victora Wagner2, Carlo Henning3
1Medical Assistant, Federal University of Rio Grande do Sul, Porto Alegre, Rio Grande do Sul, Brazil; Orthopaedist and Traumatologist, Foot and Ankle Surgery Specialty, Foot and Ankle Orthopaedic Surgeon, Department of Orthopaedics, Santa Casa de Misericórdia Hospital, Porto Alegre, Rio Grande do Sul, Brazil.
Abstract:
The hallux valgus is a pathologic condition in the forefoot that often causes pain and functional limitations. Assessing all deformity components, such as the distal metatarsal articular angle (DMAA) is essential to hallux valgus treatment. Nevertheless, interobserver agreement of DMAA is poor on plain radiographs. The present study compared computed tomographic (CT) 3-dimensional (3D) reconstruction with plain radiographic measurements for measuring the DMAA. We included 43 consecutive patients (77 feet), diagnosed with hallux valgus at the orthopedic outpatient clinic at Hospital de Clínicas de Porto Alegre (Porto Alegre, Brazil) from April 2014 to June 2015 in our prospective study. The DMAAs were measured by 2 observers using CT 3D reconstruction. The results were compared between observers and with the plain radiographic measurements using the concordance correlation coefficient and the Bland-Altman plot to determine the agreement between the 2 methods. The interobserver agreement of the CT 3D measurements was high (concordance correlation coefficient 0.90; p < .001). Significant agreement was found between the plain radiographic and CT measurements (concordance correlation coefficient 0.667; p < .001). The Bland-Altman plot showed that the difference between the plain radiographic and CT measurements increased when greater DMAA values were associated with the presence of metatarsal rotation. The interobserver agreement of DMAA measurements was greater on CT 3D reconstruction than on plain radiography. The poor interobserver agreement of the radiographic DMAA might have resulted from metatarsal rotation.
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography

