Related Experiment Video
Updated: Mar 6, 2026

Orthotopic Implantation of Patient-Derived Cancer Cells in Mice Recapitulates Advanced Colorectal Cancer
Published on: February 10, 2023
Specific computed virtual chromoendoscopy for detection of peritoneal carcinomatosis: an animal study
Haythem Najah1,2, Ingrid Jouvin3,4, Samaher Besbes4
1Department of Oncologic & Digestive Surgery, AP-HP, Hospital Lariboisière, 2 rue Ambroise Paré, 75475, Paris Cedex 10, France. haythem.najah@gmail.com.
Background:
Detection of an incipient Peritoneal Carcinomatosis (PC) is still challenging, and there is a crucial need for technological improvements in order to diagnose and to treat early this condition. The aim of this study was to create a murine model of incipient PC and to explore the PC with Fujinon Intelligent Chromo Endoscopy (FICE) in order to determine the wavelengths of the white light (WL) spectre that offer the highest contrast between PC nodules and surrounding peritoneum.
Methods:
Eighteen BALB/c mice had intraperitoneal injection of murine colonic cancer CT26 cells. Peritoneal exploration with FICE was performed at different times. For each PC nodule, 1 WL and 10 FICE images were recorded. Each image was then divided into its elementary red, green and blue band images. Depending on the FICE channel, each elementary image corresponds to a specific wavelength of the WL spectre. Through numerical analysis of these images, the value of the nodule and the background peritoneum were obtained, and the contrast value was calculated. Contrast values obtained with the different wavelengths were then compared.
Results:
PC grew in all the mice. The number as well as the size of PC nodules was increasingly high depending on the day of exploration. Mean PCI was 1.6 ± 1.2 at day 5, 7.7 ± 2.6 at day 8 and 15.0 ± 7.3 at day 10. A total number of 1805 elementary images of PC nodules were analysed. The wavelength that offered the best contrast between PC nodules and background peritoneum was 460 nm with a mean contrast value of 0.240 ± 0.151 (p < 0.0001).
Conclusion:
This murine model of incipient PC is effective, reliable and reproducible. A monochromatic light with a wavelength at 460 nm offers the highest contrast between PC nodules and background peritoneum, allowing a better detection of PC.
More Related Videos
09:42Murine Endoscopy for In Vivo Multimodal Imaging of Carcinogenesis and Assessment of Intestinal Wound Healing and Inflammation
Published on: August 26, 2014
10:28Gene Regulation and Targeted Therapy in Gastric Cancer Peritoneal Metastasis: Radiological Findings from Dual Energy CT and PET/CT
Published on: January 22, 2018
Related Concept Videos
Imaging Studies III: Gastrointestinal Motility Studies and Virtual Colonoscopy
Radionuclide Testing
Radionuclide testing is a sophisticated medical technique for assessing gastrointestinal motility. It focuses on gastric emptying and colonic transit time. Radioactive markers track the movement of food through the digestive system, providing insights into gastrointestinal disorders.
In gastric emptying studies, a meal's liquid and...
Endoscopic Procedures III: Video Capsule Endoscopy