Related Experiment Video
Updated: Mar 6, 2026

A Simple Method for Automated Solid Phase Extraction of Water Samples for Immunological Analysis of Small Pollutants
Published on: January 1, 2016
Disk-based solid phase extraction for the determination of diclofenac and steroidal estrogens E1, E2 and EE2 listed
1Department of Environmental Sciences, Jožef Stefan Institute, Jamova cesta 39, 1000 Ljubljana, Slovenia; Jožef Stefan International Postgraduate School, Jamova cesta 39, 1000 Ljubljana, Slovenia.
Abstract:
The aim of this study was to develop and validate an analytical method for determining estrone, 17β-estradiol, 17α-ethynyl estradiol and diclofenac in whole surface water samples at or below the limits of quantification as set out in Decision 2015/495/EU. The method is based on solid-phase extraction using Atlantic® HLB disks in a semi-automated system (SPE-DEX® 4790). The method involved extracting 10L of whole surface water samples followed by derivatization with N-methyl-N-(trimethylsilyl)trifluoroacetamide) and analysis by gas chromatography-mass spectrometry. Drying the disks overnight at 25°C followed by elution with ethyl acetate resulted in extraction recoveries between 75.9% and 120% and limits of quantification of 0.290ngL-1 for estrone, 1.37ngL-1 for 17β-estradiol, 0.724ngL-1 for 17α-ethynyl estradiol and 0.119ngL-1 for diclofenac. Despite extracting 10L of sample, obtained limits of quantification for 17β-estradiol and 17α-ethynyl estradiol were above those set in the Decision 2015/495/EU, while limits of quantification for estrone and diclofenac were lower. The method was applied to six Slovene surface waters, among which four contained detectable concentrations of only diclofenac (0.313ngL-1-5.69ngL-1). To our knowledge, this is the first study reporting a large volume solid-phase extraction using disks for the determination of estrone, 17β-estradiol, 17α-ethynyl estradiol and diclofenac in whole surface waters.
Related Concept Videos
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Gas Chromatography: Types of Detectors-II