Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Exploring social accountability in radiography education: Student perspectives on current practices and understanding.

Radiography (London, England : 1995)·2026
Same author

Reply to: "comment on 'convolutional neural network application for automated lung cancer detection on chest CT using Google AI Studio'".

Radiography (London, England : 1995)·2025
Same author

Convolutional neural network application for automated lung cancer detection on chest CT using Google AI Studio.

Radiography (London, England : 1995)·2025
Same author

Unusual <i>5f</i> magnetism in new kagome material UV<sub>6</sub>Sn<sub>6</sub>.

npj quantum materials·2025
Same author

I didn't get bored being on the Board.

Radiography (London, England : 1995)·2025
Same author

Professional challenges faced by student radiographers during COVID-19.

Radiography (London, England : 1995)·2025

Related Experiment Video

Updated: Mar 6, 2026

Assessing Early Stage Open-Angle Glaucoma in Patients by Isolated-Check Visual Evoked Potential
07:11

Assessing Early Stage Open-Angle Glaucoma in Patients by Isolated-Check Visual Evoked Potential

Published on: May 25, 2020

6.9K

A method to determine the impact of reduced visual function on nodule detection performance.

J D Thompson1, C Lança2, L Lança3

  • 1University of Salford, Salford M6 6PU, UK.

Radiography (London, England : 1995)
|March 15, 2017
PubMed
Summary

This study developed a method to assess how reduced vision affects nodule detection performance in radiologists. Despite visual impairment, no significant difference in nodule detection was found in this pilot study.

Keywords:
JAFROCObserver performanceVisual acuity

More Related Videos

A Swin Transformer-Based Model for Thyroid Nodule Detection in Ultrasound Images
04:23

A Swin Transformer-Based Model for Thyroid Nodule Detection in Ultrasound Images

Published on: April 21, 2023

2.4K
Author Spotlight: A 3D Digital Model for the Diagnosis and Treatment of Pulmonary Nodules
10:26

Author Spotlight: A 3D Digital Model for the Diagnosis and Treatment of Pulmonary Nodules

Published on: May 19, 2023

2.6K

Related Experiment Videos

Last Updated: Mar 6, 2026

Assessing Early Stage Open-Angle Glaucoma in Patients by Isolated-Check Visual Evoked Potential
07:11

Assessing Early Stage Open-Angle Glaucoma in Patients by Isolated-Check Visual Evoked Potential

Published on: May 25, 2020

6.9K
A Swin Transformer-Based Model for Thyroid Nodule Detection in Ultrasound Images
04:23

A Swin Transformer-Based Model for Thyroid Nodule Detection in Ultrasound Images

Published on: April 21, 2023

2.4K
Author Spotlight: A 3D Digital Model for the Diagnosis and Treatment of Pulmonary Nodules
10:26

Author Spotlight: A 3D Digital Model for the Diagnosis and Treatment of Pulmonary Nodules

Published on: May 19, 2023

2.6K

Area of Science:

  • Radiology and Medical Imaging
  • Human Factors and Observer Performance
  • Ophthalmology and Visual Science

Background:

  • Assessing the impact of reduced visual function on diagnostic accuracy is crucial for medical imaging.
  • Observer performance in tasks like nodule detection can be influenced by various factors, including visual acuity.

Purpose of the Study:

  • To validate a novel method for concurrently assessing reduced visual function and observer performance during pulmonary nodule detection.
  • To investigate the effect of induced visual defocus on radiologists' ability to detect simulated pulmonary nodules.

Main Methods:

  • Three consultant radiologists performed a nodule detection task under three conditions: no defocus (0.00 D), mild defocus (-1.00 D), and moderate defocus (-2.00 D).
  • Visual function (acuity and stereoacuity) was assessed before each evaluation. The task involved 50 abnormal and 25 normal cases with simulated nodules of varying sizes and densities.
  • Data were analyzed using the Rjafroc (Radiological Journal of the American College of Radiology) free-response receiver operating characteristic analysis.

Main Results:

  • While induced defocus negatively impacted visual acuity and stereoacuity for some observers, these effects did not lead to a statistically significant difference in nodule detection performance (p=0.130).
  • The proposed method allowed for the concurrent assessment of visual function and nodule detection performance.

Conclusions:

  • A method for evaluating the combined impact of visual function and observer performance in nodule detection tasks has been proposed and piloted.
  • This pilot evaluation did not reveal a significant difference in nodule detection performance when visual function was experimentally reduced using lenses.