Hemolysis interference in measuring fish plasma biochemical indicators
Ali Taheri Mirghaed1, Melika Ghelichpour1, Seyyed Morteza Hoseini2
1Department of Aquatic Animal Health, Faculty of Veterinary Medicine, University of Tehran, Tehran, Iran.
Fish Physiology and Biochemistry
|March 16, 2017
Summary
Hemolysis significantly alters fish plasma biochemical parameters, affecting test results. Caution is advised when interpreting hemolyzed samples, as key indicators like albumin and potassium are notably impacted.
Area of Science:
- Aquatic toxicology
- Veterinary clinical pathology
- Biochemistry
Background:
- Hemolysis, the rupture of red blood cells, is a common issue in biological sample collection.
- Interference from hemolysis can lead to inaccurate measurements of plasma biochemical parameters.
- Understanding these interferences is crucial for reliable diagnostics in fish species.
Purpose of the Study:
- To quantify the impact of varying degrees of hemolysis on multiple plasma biochemical parameters in Huso huso.
- To assess the reliability of common biochemical assays when performed on hemolyzed fish plasma.
- To provide insights into the interpretation of clinical chemistry results from compromised samples.
Main Methods:
- Blood samples from 24 Huso huso juveniles were collected and centrifuged to obtain plasma.
- Controlled hemolysis was induced by adding 0% to 20% whole blood to plasma aliquots.
- Key biochemical parameters including albumin, total protein, electrolytes, and enzymes were measured across hemolysis levels.
Main Results:
- Significant increases were observed in albumin, alkaline phosphatase (ALP), potassium, and aspartate transaminase (AST) with increasing hemolysis.
- Total protein and phosphorus also showed marked elevations, while glucose, calcium, chloride, and alanine transaminase (ALT) exhibited smaller but significant increases.
- Plasma sodium levels remained unaffected by hemolysis in this study.
Conclusions:
- Hemolysis substantially interferes with the accurate measurement of most plasma biochemical parameters in Huso huso.
- Results from hemolyzed samples require cautious interpretation, and analysis should ideally be avoided.
- Further research is recommended to develop correction methods for hemolysis-induced alterations in fish plasma analysis.
More Related Videos
Related Concept Videos
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences
1.5K
Inductively coupled plasma–mass spectrometry (ICP–MS) is a highly selective and sensitive technique for accurate elemental analysis. Though the analysis of ICP–MS mass spectra is comparatively straightforward, it is affected by spectroscopic and non-spectroscopic interferences. Spectroscopic interferences arise when the plasma contains ionic species with an m/z value the same as the analyte ion. Spectroscopic interference can be categorized as isobaric, polyatomic ions, and...
1.5K
Atomic Absorption Spectroscopy: Interference
2.2K
Interference leads to systematic error in atomic absorption (AA) measurements by enhancing or diminishing the analytical signal or the background. These interferences can be grouped into three main categories: spectral interference, chemical interference, and physical interference.
Spectral interference occurs when signals from other elements or molecules overlap with the analyte signal, falsely elevating or masking the analyte's absorbance. This interference can be corrected using Zeeman,...
Spectral interference occurs when signals from other elements or molecules overlap with the analyte signal, falsely elevating or masking the analyte's absorbance. This interference can be corrected using Zeeman,...
2.2K