The hemodynamic response to interictal epileptic discharges localizes the seizure-onset zone
Hui Ming Khoo1,2, Yongfu Hao1, Nicolás von Ellenrieder1
1Montreal Neurological Institute and Hospital, McGill University, Montreal, Quebec, Canada.
Objective:
Intracranial electroencephalography (EEG), performed presurgically in patients with drug-resistant and difficult-to-localize focal epilepsy, samples only a small fraction of brain tissue and thus requires strong hypotheses regarding the possible localization of the epileptogenic zone. EEG/fMRI (functional magnetic resonance imaging), a noninvasive tool resulting in hemodynamic responses, could contribute to the generation of these hypotheses. This study assessed how these responses, despite their interictal origin, predict the seizure-onset zone (SOZ).
Methods:
We retrospectively studied 37 consecutive patients who underwent stereo-EEG (SEEG) and EEG/fMRI that resulted in significant hemodynamic responses. Hemodynamic response maps were co-registered to postimplantation anatomic imaging, allowing inspection of these responses in relation to SEEG electrode's location. The area containing the most significant t-value (primary cluster) explored with an electrode was assessed for concordance with SEEG-defined SOZ. Discriminant analysis was performed to distinguish the primary clusters having a high probability of localizing the SOZ.
Results:
Thirty-one patients had at least one study with primary cluster explored with an electrode, and 24 (77%) had at least one study with primary cluster concordant with the SOZ. Each patient could have multiple types of interictal discharge and therefore multiple studies. Among 59 studies from the 37 patients, 44 had a primary cluster explored with an electrode and 30 (68%) were concordant with the SOZ. Discriminant analysis showed that the SOZ is predictable with high confidence (>90%) if the primary cluster is highly significant and if the next significant cluster is much less significant or absent.
Significance:
The most significant hemodynamic response to interictal discharges delineates the subset of the irritative zone that generates seizures in a high proportion of patients with difficult-to-localize focal epilepsy. EEG/fMRI generates responses that are valuable targets for electrode implantation and may reduce the need for implantation in patients in whom the most significant response satisfies the condition of our discriminant analysis.
More Related Videos
09:57Author Spotlight: Advancing Pediatric Epilepsy Surgery in Children Through Novel Biomarkers and Enhanced Localization
Published on: September 20, 2024
09:32Network Analysis of Foramen Ovale Electrode Recordings in Drug-resistant Temporal Lobe Epilepsy Patients
Published on: December 18, 2016
Related Concept Videos
Epilepsy and Seizures: Overview
Various factors can trigger epilepsy, including genetic factors, brain damage, metabolic causes, and unknown etiology. Diagnosis of epilepsy involves electroencephalography (EEG), which...
Seizures: Classification
Seizures are typically classified into two main categories: focal and generalized seizures.
Focal Seizures
Focal seizures originate from specific regions of the brain. These seizures are further sub-classified into two types:
