Elemental Contrast X-ray Tomography Using Ross Filter Pairs with a Polychromatic Laboratory Source

Benedicta D Arhatari1, Timur E Gureyev2, Brian Abbey3

  • 1ARC Centre of Excellence in Advanced Molecular Imaging, Department of Chemistry and Physics, La Trobe University, Victoria, 3086, Australia. B.Arhatari@latrobe.edu.au.

Scientific Reports
|March 18, 2017
PubMed
Summary

This study introduces Ross filter pairs for quasi-monochromatic X-ray imaging, enhancing elemental contrast in lab-based experiments. This breakthrough improves elemental specificity for X-ray radiography and tomography.

Related Concept Videos

X-ray Imaging01:24

X-ray Imaging

German physicist Wilhelm Röntgen (1845–1923) was experimenting with electrical current when he discovered that a mysterious and invisible "ray" would pass through his flesh but leave an outline of his bones on a screen coated with a metal compound. In 1895, Röntgen made the first durable record of the internal parts of a living human: an "X-ray" image (as it came to be called) of his wife’s hand. Scientists worldwide quickly began their own experiments with...
10.8K
Electron Microscope Tomography and Single-particle Reconstruction01:07

Electron Microscope Tomography and Single-particle Reconstruction

Transmission electron microscopy (TEM) can be used to determine the 3D structure of biological samples with the help of techniques such as electron microscope tomography and single-particle reconstruction. While single-particle reconstruction can examine macromolecules and macromolecular complexes in vitro conditions only, tomography permits the study of cell components or small cells in vivo.
Electron Tomography
Electron tomography can be performed either in TEM or STEM (scanning transmission...
3.0K
Atomic Absorption Spectroscopy: Radiation and Light Sources01:13

Atomic Absorption Spectroscopy: Radiation and Light Sources

Atomic absorption spectroscopy (AAS) relies on the Beer-Lambert law, which requires that the radiation source emits a narrow range of wavelengths to match the absorption characteristics of the analyte atom. The primary criteria for choosing an appropriate radiation source in AAS is to provide a precise and intense emission at specific wavelengths that will allow accurate detection of the analyte.
Two common narrow-range 'line' sources used in AAS are hollow-cathode lamps (HCLs) and...
1.4K
Positron Emission Tomography01:29

Positron Emission Tomography

Positron emission tomography (PET) is a medical imaging technique involving radiopharmaceuticals — substances that emit short-lived radiation. Although the first PET scanner was introduced in 1961, it took 15 more years before radiopharmaceuticals were combined with the technique and revolutionized its potential.
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
7.9K