Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Ultrasound II: Endoscopic Ultrasound and FibroScan01:25

Ultrasound II: Endoscopic Ultrasound and FibroScan

924
Endoscopic Ultrasound (EUS) and FibroScan are valuable diagnostic tools in gastroenterology and hepatology, each with specific applications and techniques.
Endoscopic Ultrasound (EUS):
924
Impedances and Admittance01:23

Impedances and Admittance

2.0K
In the realm of AC circuits, passive circuit elements like resistors, inductors, and capacitors take on a different character when characterized by phasor voltage and current. Their behavior is expressed through impedance, a vital concept in AC circuit analysis.
Impedance is a measure of resistance to sinusoidal current flow in an AC circuit. Unlike their behavior in DC circuits, where inductors appear as short circuits and capacitors as open circuits, the behavior of these components in AC...
2.0K
Bode Plots Construction01:24

Bode Plots Construction

1.2K
The Bode plot is an essential tool in control system analysis, mapping the frequency response of a system through a magnitude plot and a phase plot, both against a logarithmic frequency axis. To construct a Bode plot, consider the transfer function H(ω):
1.2K
Endoscopic Procedures I: Esophagogastroduodenoscopy01:29

Endoscopic Procedures I: Esophagogastroduodenoscopy

1.7K
An Esophagogastroduodenoscopy (EGD) is a diagnostic procedure in which an endoscopist uses a flexible, lighted endoscope to visualize the upper gastrointestinal (GI) tract. The procedure includes visualizing the oropharynx, esophagus, stomach, and the first part of the small intestine, the duodenum.
During an EGD, the endoscope can be used to:
1.7K

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Parental expectations regarding the announcement of a diagnosis of a rare oral disease: a qualitative study in Marseille, France.

European archives of paediatric dentistry : official journal of the European Academy of Paediatric Dentistry·2026
Same author

Rehabilitation and return to activity after platelet-rich plasma injections in chronic tendinopathies: Consensus from international experts.

PM & R : the journal of injury, function, and rehabilitation·2026
Same author

Difficulties experienced by dentists and orthodontists regarding ethical issues when announcing the diagnosis of a rare oral disease: a qualitative study in Marseille, France.

European archives of paediatric dentistry : official journal of the European Academy of Paediatric Dentistry·2024
Same author

[Bladder augmentation in the era of botulinum toxin: Indications and results].

Progres en urologie : journal de l'Association francaise d'urologie et de la Societe francaise d'urologie·2023
Same author

Organ donation by Maastricht-III pediatric patients: Recommendations of the Groupe Francophone de Réanimation et Urgences Pédiatriques (GFRUP) and Association des Anesthésistes Réanimateurs Pédiatriques d'Expression Française (ADARPEF). Part II: Specific organizational and technical considerations.

Archives de pediatrie : organe officiel de la Societe francaise de pediatrie·2022
Same author

[Home uroflowmetry technics and clinical relevance: A narrative review].

Progres en urologie : journal de l'Association francaise d'urologie et de la Societe francaise d'urologie·2022

Related Experiment Video

Updated: Mar 6, 2026

Author Spotlight: Advancements in Impedance Monitoring for Cochlear Implant Surgery
06:54

Author Spotlight: Advancements in Impedance Monitoring for Cochlear Implant Surgery

Published on: August 4, 2023

1.9K

Relationship between functional endoscopy and impedance-pH measurement.

F Michel1,2, T Stroh3,4, R Fritsche3,4

  • 1Refluxcenter Darmstadt, Darmstadt, Germany. ohrweh@me.com.

HNO
|March 18, 2017
PubMed
Summary

Functional endoscopy (VPE) shows promise for diagnosing extra-esophageal reflux symptoms, correlating well with impedance-pH monitoring results. This aids in identifying the link between reflux and symptoms.

Keywords:
Esophageal pH monitoringExtra-esophageal refluxFunctional endoscopyLaryngitisTransnasal esophagoscopy

More Related Videos

Electric Cell-substrate Impedance Sensing for the Quantification of Endothelial Proliferation, Barrier Function, and Motility
12:30

Electric Cell-substrate Impedance Sensing for the Quantification of Endothelial Proliferation, Barrier Function, and Motility

Published on: March 28, 2014

61.3K
Construction of a Wireless-Enabled Endoscopically Implantable Sensor for pH Monitoring with Zero-Bias Schottky Diode-based Receiver
08:25

Construction of a Wireless-Enabled Endoscopically Implantable Sensor for pH Monitoring with Zero-Bias Schottky Diode-based Receiver

Published on: August 27, 2021

3.0K

Related Experiment Videos

Last Updated: Mar 6, 2026

Author Spotlight: Advancements in Impedance Monitoring for Cochlear Implant Surgery
06:54

Author Spotlight: Advancements in Impedance Monitoring for Cochlear Implant Surgery

Published on: August 4, 2023

1.9K
Electric Cell-substrate Impedance Sensing for the Quantification of Endothelial Proliferation, Barrier Function, and Motility
12:30

Electric Cell-substrate Impedance Sensing for the Quantification of Endothelial Proliferation, Barrier Function, and Motility

Published on: March 28, 2014

61.3K
Construction of a Wireless-Enabled Endoscopically Implantable Sensor for pH Monitoring with Zero-Bias Schottky Diode-based Receiver
08:25

Construction of a Wireless-Enabled Endoscopically Implantable Sensor for pH Monitoring with Zero-Bias Schottky Diode-based Receiver

Published on: August 27, 2021

3.0K

Area of Science:

  • Gastroenterology
  • Diagnostic Medicine
  • Reflux Disease Research

Background:

  • Traditional diagnostic tools struggle to link extra-esophageal symptoms with pathological reflux.
  • Functional endoscopy, specifically video panendoscopy (VPE), is a potential new method.
  • Objective data on VPE's success in reflux diagnostics are lacking.

Purpose of the Study:

  • To investigate the relationship between endoscopic findings from VPE and impedance-pH monitoring in patients with extra-esophageal reflux symptoms.
  • To objectively verify the diagnostic utility of VPE in this patient group.

Main Methods:

  • Video panendoscopy (VPE) was performed on patients with extra-esophageal reflux symptoms.
  • Impedance-pH monitoring, the gold standard for esophageal reflux diagnostics, was conducted.
  • Correlation analysis between VPE findings and impedance-pH parameters was performed.

Main Results:

  • Pathological findings during VPE demonstrated a significant correlation with key impedance-pH monitoring parameters.
  • Specifically, correlations were observed with the number of reflux episodes, fraction time, and DeMeester score.
  • This supports the utility of VPE in assessing reflux activity.

Conclusions:

  • Video panendoscopy (VPE) findings correlate objectively with impedance-pH monitoring results in patients experiencing extra-esophageal reflux symptoms.
  • VPE appears to be a valuable tool for diagnosing the causal relationship between reflux and these symptoms.