Objective:
Cooling devices (CDs) worn under personal protective equipment (PPE) can alleviate some of the heat stress faced by health care workers responding to the Ebola outbreak in West Africa.
Methods:
Six healthy, young individuals were tested while wearing 4 different CDs or no cooling (control) under PPE in an environmental chamber (32°C/92% relative humidity) while walking (3 METs, 2.5 mph, 0% grade) on a treadmill for 60 minutes. Exercise was preceded by a 15-minute stabilization period and a 15-minute donning period.
Results:
The control condition resulted in a significantly higher rectal temperature (Tre) at the end of the exercise than did all CD conditions (CD1, P=0.004; CD2, P=0.01; CD3, P=0.000; CD4, P=0.000) with CD1 and CD2 resulting in a higher Tre than CD3 and CD4 (P<0.05). The control condition resulted in a higher heart rate (HR) at the end of exercise than did the CD3 (P=0.01) and CD4 (P=0.009) conditions, whereas the HR of the CD1 and CD2 conditions was higher than that of the CD3 and CD4 conditions (P<0.05). Weight loss in the control condition was higher than in the CD3 (P=0.003) and CD4 (P=0.01) conditions. Significant differences in subjective measurements of thermal stress were found across conditions and time.
Conclusions:
Use of CDs can be advantageous in decreasing the negative physiological and subjective responses to the heat stress encountered by health care workers wearing PPE in hot and humid environments. (Disaster Med Public Health Preparedness. 2017;11:573-579).
Related Concept Videos
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Assessing Body Temperature - Oral
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...
Assessing Body Temperature - Axilla
Step 1: Perform hand hygiene and put on clean gloves to maintain infection control and prevent cross-contamination.
Step 2: Prepare the patient by explaining the procedure to ensure understanding and cooperation. Ensure privacy, expose the axilla, and inform the patient that minimal movement is crucial for an accurate reading.
Step 3: Adjust the patient’s clothing to expose only the axilla. It minimizes...
Personal Protective Equipment
Assessing Body Temperature - Rectal
Follow these steps for rectal temperature assessment:
Step 1: Perform hand hygiene and don clean gloves to prevent cross-infection.
Step 2: Position the patient in a side-lying position to better visualize the rectal...
Assessing Body Temperature - Tympanic membrane
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...