Related Experiment Video
Updated: Mar 6, 2026

Elaborate Control of Inkjet Printer for Fabrication of Chip-based Supercapacitors
Published on: November 30, 2021
[Results of the GECO series]
1Centre de Traumatologie et d'Orthopédie, 10, avenue A. Baumann, F-67400, Illkirch-Graffenstaden, France.
Abstract:
301 hip prostheses were implanted in patients under the age of 50 years. All patients were followed for a minimal period of 3 years or until revision. The young age is due to the etiologies: femoral head necrosis, congenital hip dislocation, post-traumatic arthrosis. The implanted prostheses were of different types: both components were usually cementless; most bearing surfaces were alumina-polyethylene, with a head diameter of 32 or 28 mm. Patients were followed for 3 to 18 years after implantation (mean: 7 years). At the last follow-up, 59 prostheses (20%) had been exchanged; 232 cases had a good functional result according to Merle d'Aubigné (77% of the whole series and 96% of the surviving prostheses). The non revised patients mostly had an excellent result with regard to pain, range of motion and gait, and 85% returned to work.The final X-ray examinations of surviving prostheses showed 22% acetabular and 25% femoral radiolucent lines without loosening, 7% severe acetabular polyethylene wear. 3% of acetabular and 9% of femoral prostheses had migrated, mostly during the first months after cementless implantation with subsequent stabilisation.Revisions were performed after 6 months to 16 years. Main reasons were primary instability of a cementless implant (14 cases), secondary instability of a cementless implant (18 cases) and loosening of a cemented implant (18 cases). The global survival rate is 67% after 10 years, and 47% after 14 years. The survival rate of cemented cups was higher than screwed uncemented cups after 12 years (73% vs 59% - p<0,05), and there was no difference with uncemented press-fit cups after 7 years (95% vs 90%). The survival rate of cemented cups was higher than uncoated uncemented cups after 13 years(67% vs 53% -p<0,05), and there was no difference with hydroxyapatite-coated uncemented cups after 5 years (97% vs 93%). There was no difference between survival rates of cemented or cementless femoral prosthesis after 12 years (63% vs 54%) with respect to the presence or absence of hydroxyapatite. There was no difference between the survival rates of all bearing surfaces after 5 and 11 years, but none of the zirconia-polyethylene bearings had been revised after 5 years. There was no difference between survival rates of 28 mm and 32 mm heads after 8 years (86% vs 78%).Cemented prostheses are clearly indicated for patients under 50. Screwed uncemented cups are no longer indicated. Uncemented prostheses showed no better survival than cemented ones. Zirconia-polyethylene bearings could lead to a better survival rate than alumina-polyethylene or steel-polyethylene bearings.
More Related Videos
08:59Synthesizing a Gel Polymer Electrolyte for Supercapacitors, Assembling a Supercapacitor Using a Coin Cell, and Measuring Gel Electrolyte Performance
Published on: November 30, 2022
12:00Evaluating the Electrochemical Properties of Supercapacitors using the Three-Electrode System
Published on: January 7, 2022
Related Concept Videos
Turnover Number and Catalytic Efficiency
Chymotrypsin is a pancreatic enzyme that breaks down proteins during digestion....
Series and Parallel Inductors
For a series connection of N inductors, each carrying the same current, applying Kirchhoff's voltage law unveils a crucial relationship. Substituting the expression for...
Series and Parallel Capacitors
First, consider capacitors connected in series to a battery. In this configuration, the plate connected to the battery's positive terminal develops a positive charge, while the plate attached to the negative terminal becomes negatively charged. An equal magnitude of charge is induced on the...
Internal Combustion Engine
Energy Line and Hydraulic Gradient Line
Generator Voltage Control