Related Experiment Video
Updated: Mar 6, 2026

Deep Proteome Profiling by Isobaric Labeling, Extensive Liquid Chromatography, Mass Spectrometry, and Software-assisted Quantification
Published on: November 15, 2017
Scrambled Internal Standard Method for High-Throughput Protein Quantification by Matrix-Assisted Laser Desorption
Toshihiro Yoneyama1, Sumio Ohtsuki2,3, Masanori Tachikawa1
1Division of Membrane Transport and Drug Targeting, Graduate School of Pharmaceutical Sciences, Tohoku University , Aoba, Aramaki, Aoba-ku, Sendai 980-8578, Japan.
Abstract:
Matrix-assisted laser desorption ionization (MALDI) could be advantageous for high-throughput MS acquisition but suffers from low signal reproducibility. The purpose of this study was to establish a reliable MALDI-tandem mass spectrometry (MS/MS)-based high-throughput quantification of tryptic peptides using our newly developed scrambled internal standard (sIS) method. The standard curves obtained with sIS peptides showed good linearity over a wide concentration range (5-1000 fmol/μL) compared to that with the IS-free method, and the coefficient of variation of data points at each concentration (5-1000 fmol/μL) was significantly reduced. Furthermore, the ion suppression effect of digested serum could be normalized with the sIS peptides. Differences of quantitative values obtained by MALDI-MS/MS and liquid chromatography-MS/MS with selected reaction monitoring were within 20% in the presence of 0.1-5 μL of immunoprecipitated model plasma. Furthermore, the effect of amino acid composition on peptide sensitivity was examined, and we found that sensitivity was significantly decreased if an aromatic amino acid was replaced with a nonaromatic amino acid. Thus, high sensitivity required the use of sIS peptides containing an aromatic amino acid. Finally, the sIS method enabled high-throughput quantification of tryptic peptides with high accuracy and a wide dynamic range.
More Related Videos
07:49Matrix-assisted Laser Desorption/Ionization Time of Flight MALDI-TOF Mass Spectrometric Analysis of Intact Proteins Larger than 100 kDa
Published on: September 9, 2013
11:09An HS-MRM Assay for the Quantification of Host-cell Proteins in Protein Biopharmaceuticals by Liquid Chromatography Ion Mobility QTOF Mass Spectrometry
Published on: April 17, 2018
Related Concept Videos
MALDI-TOF Mass Spectrometry
Peptide Identification Using Tandem Mass Spectrometry
This technique helps gather information regarding the protein from which the peptide was obtained and to study the peptides’ amino acid sequence. Identifying peptides from a complex mixture is an important component of the growing field of...
Matrix-Assisted Laser Desorption Ionization (MALDI)