Abstract:
Objective/Background: To evaluate the performance of a multisensor sleep-tracker (ŌURA ring) against polysomnography (PSG) in measuring sleep and sleep stages. Participants: Forty-one healthy adolescents and young adults (13 females; Age: 17.2 ± 2.4 years). Methods: Sleep data were recorded using the ŌURA ring and standard PSG on a single laboratory overnight. Metrics were compared using Bland-Altman plots and epoch-by-epoch (EBE) analysis. Results: Summary variables for sleep onset latency (SOL), total sleep time (TST), and wake after sleep onset (WASO) were not different between ŌURA ring and PSG. PSG-ŌURA discrepancies for WASO were greater in participants with more PSG-defined WASO (p < .001). Compared with PSG, ŌURA ring underestimated PSG N3 (~20 min) and overestimated PSG REM (~17 min; p < .05). PSG-ŌURA differences for TST and WASO lay within the ≤ 30 min a-priori-set clinically satisfactory ranges for 87.8% and 85.4% of the sample, respectively. From EBE analysis, ŌURA ring had a 96% sensitivity to detect sleep, and agreement of 65%, 51%, and 61%, in detecting "light sleep" (N1), "deep sleep" (N2 + N3), and REM sleep, respectively. Specificity in detecting wake was 48%. Similarly to PSG-N3 (p < .001), "deep sleep" detected with the ŌURA ring was negatively correlated with advancing age (p = .001). ŌURA ring correctly categorized 90.9%, 81.3%, and 92.9% into PSG-defined TST ranges of < 6 hr, 6-7 hr, > 7 hr, respectively. Conclusions: Multisensor sleep trackers, such as the ŌURA ring have the potential for detecting outcomes beyond binary sleep-wake using sources of information in addition to motion. While these first results could be viewed as promising, future development and validation are needed.
More Related Videos
05:51Assessing the Accuracy of Fitness Smartwatch Data for Cardiovascular and Physical Activity Monitoring: A Validation Study in Digital Health
Published on: February 21, 2025
08:36Collecting Sleep, Circadian, Fatigue, and Performance Data in Complex Operational Environments
Published on: August 8, 2019
Related Concept Videos
Sleep Apnea
The condition is more prevalent among...
REM Sleep Behavior Disorder
RBD is significantly associated with...
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Understanding Sleep
The circadian rhythm, a nearly 24-hour cycle, is deeply influenced by environmental light cues. Light exposure directly affects the hypothalamus, which in turn regulates...
Sleep-Wake Cycles
NREM Sleep
NREM sleep comprises four progressive stages that seamlessly merge:
Stages of Sleep
Before sleep begins, in wakefulness, the brain exhibits primarily beta waves, which are high in frequency and low in amplitude, indicating alertness...