Related Experiment Video
Updated: Mar 6, 2026

Coherence between Brain Cortical Function and Neurocognitive Performance during Changed Gravity Conditions
Published on: May 23, 2011
Evidence for -Gz Adaptation Observed with Wearable Biosensors During High Performance Jet Flight
G Merrill Rice1, Dallas Snider, Jeffrey L Moore
1Naval Aerospace Medicine Institute, NAS Penscola, Pensacola, FL., USA.
Introduction:
Few studies have evaluated physiological responses to high acceleration forces during actual flight and to our knowledge no normative data has been acquired by technologies such as wearable biosensors during high performance jet aircraft operations.
Methods:
In-flight physiological data from an FDA cleared portable triaxial accelerometer and bio-sensor were observed from five active duty F-18 pilots of the Naval Flight Demonstration Squadron (Blue Angels). Of the five pilots, three were formation pilots who flew lower G profiles and two were solo pilots who flew higher G profiles. Physiological parameters monitored were heart rate, respiratory rate, temperature, caloric expenditure, and duration of exposure to levels of acceleration.
Results:
Evaluated were 25 practice demonstration flights; 9 flights were excluded secondary to incomplete or inaccurate physiological data. We observed no significant bradycardia during a total of 189 maneuvers which met inclusion criteria for push-pull events (PPE) or isolated -Gz exposures. Further analysis of 73 PPE revealed an overall significant rise in HR following the PPE, where mean heart rate was 106 (95% CI, 100:112) at the beginning of the push and 129 (95% CI, 123:135) following the pull.
Discussion:
A majority of the flights monitored provided reliable physiological data. Initial data suggests, contrary to currently held aeromedical doctrine, maneuvers such as the "push-pull" do not evoke vasovagal based bradycardic responses in aerobatic pilots. Possible explanations for these findings are sympathetic nervous system activation through adaptation and/or sustained isometric resistance from control inputs, both of which are areas of future research for our team.Rice GM, Snider D, Moore JL, Lavan JT, Folga R, VanBrunt TB. Evidence for -Gz adaptation observed with wearable biosensors during high performance jet flight. Aerosp Med Hum Perform. 2016; 87(12):996-1003.
More Related Videos
07:48Eye Tracking During A Complex Aviation Task For Insights Into Information Processing
Published on: April 4, 2025
13:59Reduced-gravity Environment Hardware Demonstrations of a Prototype Miniaturized Flow Cytometer and Companion Microfluidic Mixing Technology
Published on: November 13, 2014
Related Concept Videos
Measuring Acceleration Due to Gravity
A simple pendulum can be described as a point mass and a string. Meanwhile, a physical pendulum is any object whose oscillations are similar to a simple pendulum, but cannot be modeled as a point mass on a string because its mass is distributed over a larger area. The behavior of a physical pendulum can be modeled using the principles of...
Physiological Barriers
The blood endothelial barrier is the most porous of these. It allows all small ionized, un-ionized, and lipophilic molecules to pass through the endothelial lining into the interstitial space...