A preliminary study on multi-wavelength PPG based pulse transit time detection for cuffless blood pressure
Abstract:
Pulse transit time (PTT) has been widely studied as an index of blood pressure (BP) changes. In recent years, some prototypes of PTT-based wearable BP measurement devices have been developed, which can relieve users from the discomfort caused by the inflating cuff used in auscultatory and oscillometric BP measurement techniques. However, in the common practice for PTT detection, multi-site sensor implementation on human body is required, making it difficult for the integration of wearable devices. Since multi-wavelength (MW) photoplethysmogram (PPG) signals carry blood pulsation information of different blood vessels embedded in different skin depths, the time difference between different wavelength PPG signals collected at the same body site can be treated as a special PTT on a short length of blood vessels beneath the skin. In this work, the time difference between MW PPG, denoted as PTT_MW, was explored to track BP changes as a substitute of infrared (IR) PTT_EP. (PTT_EP is the time interval between electrocardiogram (ECG) and IR PPG.) Ten healthy adult subjects participated in the experiment, and their continuous BP, ECG and fingertip MW PPG signals generated from blue, green, yellow and IR light were recorded after 2-minute static handgrip exercise at 33% maximal voluntary contraction. The results showed that the correlation between Systolic BP (SBP) and IR-Blue PTT_MW (|r|= 0.52) was comparable to the correlation between SBP and IR PTT_EP (|r|= 0.59). Moreover, we optimized the wavelength combination of PTT_MWs for each subject and found the average value of optimal correlation between SBP and PTT_MW reached 0.76, which was significantly (p<;0.01) higher than the correlation between IR PTT_EP and SBP. This study reveals that the time difference between MW PPG can be potentially used as PTT for cuffless BP measurement with its unique advantage in simple sensor implementation at only one body site.
More Related Videos
14:28Non-Invasive Monitoring of Microvascular Oxygenation and Reactive Hyperemia using Hybrid, Near-Infrared Diffuse Optical Spectroscopy for Critical Care
Published on: May 10, 2024
05:51Measuring the Carotid to Femoral Pulse Wave Velocity Cf-PWV to Evaluate Arterial Stiffness
Published on: May 3, 2018
Related Concept Videos
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Assessment of blood pressure in brachial artery(two-step method)
Pre-Procedural Guidelines for Assessing Blood Pressure
Special considerations while measuring pulse
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...