Related Experiment Video
Updated: Mar 5, 2026

Measuring 3D In-vivo Shoulder Kinematics using Biplanar Videoradiography
Published on: March 12, 2021
Reference Values for the Scalene Interval Width During Varying Degrees of Glenohumeral Abduction Using
Ross Mattox1, Patrick J Battaglia1, Aaron B Welk1
1Department of Radiology, Logan University, Chesterfield, MO.
Objective:
The aim of this study was to establish reference values for the width of the interval between the anterior and middle scalene muscles using ultrasonography during varying degrees of glenohumeral joint (GH) abduction. Reliability and body mass index (BMI) data were also assessed.
Methods:
Interscalene triangles of asymptomatic participants were scanned bilaterally in the transverse plane. Images were obtained at 0°, 90°, and 150° of GH abduction with the participant seated. Width measurements were taken between the anterior and middle scalene muscle borders by bisecting the C6 nerve root as it passed superficial to the posterior tubercle of the C7 transverse process. Intra- and interexaminer reliability and BMI correlation were studied. Statistical significance was defined as P ≤ .05.
Results:
Images of 42 scalene intervals were included from 21 participants (11 female). Mean participant age was 25.3 ± 3.9 years; mean BMI was 25.4 ± 2.7 kg/m2. Scalene interval measurements at 0°, 90°, and 150° of GH abduction were 4.5 ± 0.5 mm, 4.6 ± 0.5 mm, and 4.4 ± 0.7 mm, respectively, without a significant difference (P = .07). Intraexaminer reliability was excellent (0°: intraclass correlation coefficient [ICC] = 0.82; 90°: ICC = 0.89; 150°: ICC = 0.90). Interexaminer reliability was good to excellent (0°: ICC = 0.59; 90°: ICC = 0.85; 150°: ICC = 0.89). Body mass index was positively correlated only at 0° of GH abduction.
Conclusions:
This study establishes previously unreported reference ultrasonography values for the width of the scalene interval. Intraexaminer reliability was excellent at all glenohumeral positions, and interexaminer reliability was determined to be good to excellent. Body mass index was positively correlated only at 0° of GH abduction.
More Related Videos
Related Concept Videos
Ultrasonography
During an ultrasonography procedure, a handheld device called...
Imaging Studies II: Ultrasonography
Ultrasound I: Abdominal Ultrasonography
Abdominal ultrasonography, commonly known as abdominal ultrasound, is a vital, non-invasive medical imaging technique widely used in healthcare.
Procedure:
This diagnostic tool allows the clinician to visually inspect internal structures within the abdomen, including vital organs such as the liver, gallbladder, pancreas, kidneys, and spleen.
The abdominal ultrasound process begins with applying a special gel to the patient's skin over the abdomen. This gel enhances the...

