Related Experiment Video
Updated: Mar 5, 2026

Analysis of Craniomaxillofacial Malformations in Mice Using Three-dimensional Microcomputed Tomography
Published on: January 17, 2025
Accuracy and reliability of cetacean cranial measurements using computed tomography three dimensional volume rendered
Adams Hei Long Yuen1, Henry Chun Lok Tsui1, Brian Chin Wing Kot1,2
1School of Medical and Health Sciences, Tung Wah College, Homantin, Kowloon, Hong Kong SAR, China.
Abstract:
Computed tomography (CT) has become more readily available for post-mortem examination, offering an alternative to cetacean cranial measurements obtained manually. Measurement error may result in possible variation in cranial morphometric analysis. This study aimed to evaluate the accuracy and reliability of cetacean cranial measurements obtained by CT three-dimensional volume rendered images (3DVRI). CT scans of 9 stranded cetaceans were performed. The acquired images were reconstructed using bone reconstruction algorithms. The reconstructed crania obtained by 3DVRI were visualized after excluding other body structures. Accuracy of cranial measurements obtained by CT 3DVRI was evaluated by comparing with that obtained by manual approach as standard of reference. Reproducibility and repeatability of cranial measurements obtained by CT 3DVRI were evaluated using intraclass correlation coefficient (ICC). The results demonstrated that cranial measurements obtained by CT 3DVRI yielded high accuracy (88.05%- 99.64%). High reproducibility (ICC ranged from 0.897 to 1.000) and repeatability (ICC ranged from 0.919 to 1.000 for operator 1 and ICC range from 0.768 to 1.000 for operator 2) were observed in cranial measurements obtained by CT 3DVRI. Therefore, cranial measurements obtained by CT 3DVRI could be considered as virtual alternative to conventional manual approach. This may help the development of a normative reference for current cranial maturity and discriminant analysis studies in cetaceans.
More Related Videos
12:32Image Rendering Techniques in Postmortem Computed Tomography: Evaluation of Biological Health and Profile in Stranded Cetaceans
Published on: September 27, 2020
10:23Author Spotlight: Three-Dimensional Cephalometric Landmark Annotation Demonstration on Human Cone Beam Computed Tomography Scans
Published on: September 8, 2023
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography