Related Experiment Video
Updated: Mar 5, 2026

Application of Deep Learning-Based Medical Image Segmentation via Orbital Computed Tomography
Published on: November 30, 2022
Readout-segmented echo-planar diffusion-weighted imaging in the assessment of orbital tumors: comparison with
Xiaoquan Xu1, Yanjun Wang1, Hao Hu1
11 Department of Radiology, the First Affiliated Hospital of Nanjing Medical University, Nanjing, PR China.
Abstract:
Background Readout-segmented echo-planar imaging (RS-EPI) could improve the imaging quality of diffusion-weighted imaging (DWI) in various organs. However, whether it could improve the imaging quality and diagnostic performance for the patients with orbital tumors is still unknown. Purpose To compare the image quality and diagnostic performance of RS-EPI DWI with that of conventional single-shot EPI (SS-EPI) DWI in patients with orbital tumors. Material and Methods SS-EPI and RS-EPI DW images of 32 patients with pathologically diagnosed orbital tumors were retrospectively analyzed. Qualitative imaging parameters (imaging sharpness, geometric distortion, ghosting artifacts, and overall imaging quality) and quantitative imaging parameters (apparent diffusion coefficient [ADC], signal-to-noise ratio [SNR], contrast, and contrast-to-noise ratio [CNR]) were assessed by two independent radiologists, and compared between SS-EPI and RS-EPI DWI. Receiver operating characteristic curves were used to determine the diagnostic value of ADC in differentiating malignant from benign orbital tumors. Results RS-EPI DW imaging produced less geometric distortion and ghosting artifacts, and better imaging sharpness and overall imaging quality than SS-EPI DWI (for all, P < 0.001). Meanwhile, RS-EPI DWI produced significantly lower SNR ( P < 0.001) and ADC ( P < 0.001), and higher contrast ( P < 0.001) than SS-EPI DWI, while producing no difference in CNR ( P = 0.137). There was no significant difference on the diagnostic performance between SS-EPI and RS-EPI DWI, when using ADC as the differentiating index ( P = 0.529). Conclusion Compared with SS-EPI, RS-EPI DWI provided significantly better imaging quality and comparable diagnostic performance in differentiating malignant from benign orbital tumors.
Related Concept Videos
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Imaging Studies III: Computed Tomography
Imaging Studies IV: Magnetic Resonance Imaging
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...
Magnetic Resonance Imaging
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...

