Related Experiment Video
Updated: Mar 5, 2026

Trabecular Meshwork Response to Pressure Elevation in the Living Human Eye
Published on: June 20, 2015
Effect of High Altitude Exposure on Intraocular Pressure Using Goldmann Applanation Tonometry
Gabriel Willmann1,2, Kai Schommer3, Maximilian Schultheiss2,4
11 Department of Ophthalmology, Katharinenhospital Stuttgart , Stuttgart, Germany .
Abstract:
Willmann, Gabriel, Kai Schommer, Maximilian Schultheiss, M. Dominik Fischer, Karl-Ulrich Bartz-Schmidt, Florian Gekeler, and Andreas Schatz. Effect of high altitude exposure on intraocular pressure using Goldmann applanation tonometry. High Alt Med Biol. 18:114-120, 2017.
Aims:
The aim of the study was to quantify changes of intraocular pressure (IOP) during exposure to 4559 m using the state-of-the-art method of Goldmann applanation tonometry for IOP measurement and to detect correlations between IOP and acute mountain sickness (AMS) in a prospective manner.
Methods:
IOP was measured using a Goldmann applanation tonometer AT 900® (Haag-Streit, Switzerland) and central corneal thickness (CCT) with the anterior segment module of a Spectralis™ HRA+OCT® device (Heidelberg Engineering, Germany) at baseline and high altitude. Assessment of AMS was performed using the Lake Louise and AMS-C questionnaires, and Pearson's correlation coefficient was calculated for association between IOP and AMS.
Results:
Raw IOP values at high altitude were not significantly changed compared to baseline. IOP adjusted to the increase in CCT at high altitude, which is known to alter IOP levels, showed a significant reduction for corrected IOP values on day 3 of exposure (morning -2.1 ± 1.2 mmHg; evening -2.3 ± 1.1 mmHg; p < 0.05). No correlation of IOP with AMS or clinical parameters (heart rate and SpO2) at high altitude was noted.
Conclusions:
IOP showed a significant reduction of IOP levels when corrected for increased CCT values at high altitude. Furthermore, the prospective measurement of IOP is not useful in diagnosing AMS or for the prediction of more severe high altitude related illnesses as the decrease in IOP and symptoms of AMS do not correlate during altitude exposure.
Related Concept Videos
Open Angle Glaucoma: Treatment
Drugs such as carbonic anhydrase inhibitors, α2- and...
Glaucoma: Overview
Angle Closure Glaucoma: Treatment
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Measurement of Blood Pressure