Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

An Improved Beta Burst Extraction for Chip-Based Deep Brain Stimulation With Real-Time Model Updating.

IEEE open journal of engineering in medicine and biology·2026
Same author

Hypertension-associated gut dysbiosis drives target organ damage through impaired polyunsaturated fatty acids metabolism and immune activation.

Pharmacological research·2026
Same author

Deciphering the impact of light-dark cycles on the interaction between cyanophage YongM and Nostoc sp. FACHB-596.

Environmental research·2026
Same author

Research progress of tertiary lymphoid structure in hepatocellular carcinoma: from prognostic biomarkers to new strategies for immunotherapy.

Frontiers in immunology·2026
Same author

An interpretable deep learning diagnostic framework for early Alzheimer's disease based on EEG microstate spectra and multi-branch CNN.

Journal of neuroengineering and rehabilitation·2026
Same author

Linkage of gut microbiota dysbiosis to chronic kidney disease in patients with graded proteinuria levels.

Microbiology spectrum·2026
Same journal

Multiplexed Crossbar GFET Array With BioADC for Multi-Modal Aptamer-Based Sensing.

IEEE transactions on biomedical circuits and systems·2026
Same journal

A VPG-Based Adaptive Windowing PPG Sensor IC for Low-Power Wearable Monitoring.

IEEE transactions on biomedical circuits and systems·2026
Same journal

A Chopper Amplifier with Feedforward SAR ADC Assisted DC Servo Loop Achieving ±1V DC Offset Cancellation in 2.1s for Neural Signal Recordings.

IEEE transactions on biomedical circuits and systems·2026
Same journal

ANP-R: A 22nm 0.88pJ/SOP Asynchronous SNN-based Processor with Coarse-Grained Reconfigurable Architecture Enabling Multisensory On-chip Incremental Learning for Edge AI.

IEEE transactions on biomedical circuits and systems·2026
Same journal

A High-Efficiency Neural Processing SoC for Adaptive Closed-Loop Neuromodulation.

IEEE transactions on biomedical circuits and systems·2026
Same journal

DustNet: A Wireless Network of Ultrasonic Neural Implants.

IEEE transactions on biomedical circuits and systems·2026
See all related articles

Related Experiment Video

Updated: Mar 5, 2026

A Microfluidic-based Electrochemical Biochip for Label-free DNA Hybridization Analysis
14:53

A Microfluidic-based Electrochemical Biochip for Label-free DNA Hybridization Analysis

Published on: September 10, 2014

17.9K

Droplet Size-Aware High-Level Synthesis for Micro-Electrode-Dot-Array Digital Microfluidic Biochips.

Zipeng Li, Kelvin Yi-Tse Lai, Po-Hsien Yu

    IEEE Transactions on Biomedical Circuits and Systems
    |March 24, 2017
    PubMed
    Summary
    This summary is machine-generated.

    Researchers developed a novel synthesis approach for microelectrode-dot-array (MEDA) biochips, enabling automated biochemistry experiments. This method addresses limitations of existing digital microfluidic biochip (DMFB) technologies for MEDA architectures.

    More Related Videos

    Dry Film Photoresist-based Electrochemical Microfluidic Biosensor Platform: Device Fabrication, On-chip Assay Preparation, and System Operation
    13:42

    Dry Film Photoresist-based Electrochemical Microfluidic Biosensor Platform: Device Fabrication, On-chip Assay Preparation, and System Operation

    Published on: September 19, 2017

    12.6K
    Generation of Dynamical Environmental Conditions using a High-Throughput Microfluidic Device
    14:48

    Generation of Dynamical Environmental Conditions using a High-Throughput Microfluidic Device

    Published on: April 17, 2021

    4.6K

    Related Experiment Videos

    Last Updated: Mar 5, 2026

    A Microfluidic-based Electrochemical Biochip for Label-free DNA Hybridization Analysis
    14:53

    A Microfluidic-based Electrochemical Biochip for Label-free DNA Hybridization Analysis

    Published on: September 10, 2014

    17.9K
    Dry Film Photoresist-based Electrochemical Microfluidic Biosensor Platform: Device Fabrication, On-chip Assay Preparation, and System Operation
    13:42

    Dry Film Photoresist-based Electrochemical Microfluidic Biosensor Platform: Device Fabrication, On-chip Assay Preparation, and System Operation

    Published on: September 19, 2017

    12.6K
    Generation of Dynamical Environmental Conditions using a High-Throughput Microfluidic Device
    14:48

    Generation of Dynamical Environmental Conditions using a High-Throughput Microfluidic Device

    Published on: April 17, 2021

    4.6K

    Area of Science:

    • Biochemistry
    • Microfluidics
    • Bioengineering

    Background:

    • Digital microfluidic biochips (DMFBs) offer automated laboratory solutions.
    • Microelectrode-dot-array (MEDA) architectures are a recent advancement in DMFBs.
    • Existing synthesis methods are incompatible with MEDA biochips due to architectural differences.

    Purpose of the Study:

    • To present the first synthesis approach specifically for MEDA biochips.
    • To enable automated biochemistry mapping on MEDA platforms.
    • To overcome the limitations of current DMFB synthesis techniques for MEDA architectures.

    Main Methods:

    • Developed a general analytical model for droplet velocity in MEDA biochips.
    • Validated the droplet velocity model experimentally on a fabricated MEDA biochip.
    • Proposed a novel synthesis method covering reservoir placement, operation scheduling, module placement, droplet routing, and diagonal movement.

    Main Results:

    • The analytical model for droplet velocity was experimentally validated.
    • Simulations and experimental results confirmed the effectiveness of the proposed synthesis technique.
    • The new method successfully addresses key aspects of MEDA biochip design and operation.

    Conclusions:

    • The presented synthesis approach is effective for MEDA biochips.
    • This work enables the utilization of MEDA architectures for automated biochemistry.
    • The developed method represents a significant advancement in DMFB technology for MEDA platforms.