Optimal method of measuring the T-peak to T-end interval for risk stratification in primary prevention
Todd M Rosenthal1, Daniel Masvidal1, Freddy M Abi Samra1
1Department of Cardiology, Ochsner Medical Center, 1514 Jefferson Highway, New Orleans, LA 70121, USA.
Aims:
Several published investigations demonstrated that a longer T-peak to T-end interval (Tpe) implies increased risk for ventricular tachyarrhythmia (VT/VF) and mortality. Tpe has been measured using diverse methods. We aimed to determine the optimal Tpe measurement method for screening purposes.
Methods And Results:
We evaluated 305 patients with LVEF ≤ 35% and an implantable cardioverter-defibrillator implanted for primary prevention. Tpe was measured using seven different methods described in the literature, including six manual methods and the automated algorithm '12SL', and was corrected for heart rate. Endpoints were VT/VF and death. To account for differences in the magnitude of Tpe measurements, results are expressed in standard deviation (SD) increments. We evaluated the clinical utility of each measurement method based on predictive ability, fraction of immeasurable tracings, and intra- and interobserver correlation. >Over 31 ± 23 months, 82 (27%) patients had VT/VF, and over 49 ± 21 months, 91 (30%) died. Several rate-corrected Tpe measurement methods predicted VT/VF (HR per SD 1.20-1.34; all P < 0.05), and nearly all methods (both corrected and uncorrected) predicted death (HR per SD 1.19-1.35; all P < 0.05). Optimal predictive ability, readability, and correlation were found in the automated 12SL method and the manual tangent method in lead V2.
Conclusion:
For the prediction of VT/VF, the utility of Tpe depends upon the measurement method, but for the prediction of mortality, most published Tpe measurement methods are similarly predictive. Heart rate correction improves predictive ability. The automated 12SL method performs as well as any manual measurement, and among manual methods, lead V2 is most useful.
More Related Videos
07:40Impact of High-intensity Interval Exercise and Moderate-Intensity Continuous Exercise on the Cardiac Troponin T Level at an Early Stage of Training
Published on: October 10, 2019
12:00Evaluation of a Novel Laser-assisted Coronary Anastomotic Connector - the Trinity Clip - in a Porcine Off-pump Bypass Model
Published on: November 24, 2014
Related Concept Videos
Kaplan-Meier Approach
Comparing Experimental Results: Student's t-Test
Actuarial Approach
Consider the example of a high-risk surgical procedure with significant early-stage mortality. A two-year clinical study is conducted,...
Types of Biopharmaceutical Studies: Controlled and Non-Controlled Approaches
Non-controlled studies, commonly employed for initial exploration, lack a control group, rendering them susceptible to biases and external influences. In contrast,...
Therapeutic Drug Monitoring: Overview and Classification