Benchmark integral neutron experiments for Fe, Be and C with DT neutron by liquid scintillation detector
1Institute of Nuclear Physics and Chemistry, China Academy of Engineering Physics, Mianyang 621900, People's Republic of China.
Abstract:
The measurements of iron, beryllium and carbon sphere neutron leakage spectra using BC501A detector by DT neutron source are presented. The experiments were carried out in Institute of Nuclear Physics and Chemistry (INPC), China. Neutron leakage spectra in a wide energy range at angles of 0° and 30° from the direction of incident deuteron beam were obtained. The results show the leakage neutron flux decreases notably with the spherical shell increasing when neutron energy >10MeV. When neutron energy <6MeV the leakage neutron distribution tends to lower energy side with the shell increase. The total uncertainty evaluation of the neutron spectra is also provided: in the high-energy parts the uncertainty is about 5-7%, while in the low-energy parts the uncertainty is about 7-9%. In order to compare the experiment results a Monte-carlo calculation was made using the MCNP5 Code with the ENDF/B-VII.1 nuclear data files.
More Related Videos
11:27Studying Soft-matter and Biological Systems over a Wide Length-scale from Nanometer and Micrometer Sizes at the Small-angle Neutron Diffractometer KWS-2
Published on: December 8, 2016
08:48High-Resolution Neutron Spectroscopy to Study Picosecond-Nanosecond Dynamics of Proteins and Hydration Water
Published on: April 28, 2022
Related Concept Videos
Nuclear Transmutation
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Insensitive Nuclei Enhanced by Polarization Transfer (INEPT)
Double Resonance Techniques: Overview
Spin decoupling is usually achieved by...
Atomic Emission Spectroscopy: Instrumentation
Chemical Shift: Internal References and Solvent Effects
The internal reference compound generally used in NMR spectroscopy is tetramethylsilane (TMS). TMS is preferred because it is chemically inert, soluble in NMR solvents, and easily removable. Also, the highly shielded methyl protons in TMS yield an intense...