Gas Chromatography-Mass Spectrometry Paired with Total Vaporization Solid-Phase Microextraction as a Forensic Tool
Published on: May 25, 2021
Simultaneous detection of chlorinated polycyclic aromatic hydrocarbons with polycyclic aromatic hydrocarbons by gas
Meng Qiao1, Wei Cao1, Bochuan Liu1
1Key Laboratory of Drinking Water Science and Technology, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing, 100085, China.
Abstract:
Chlorinated polycyclic aromatic hydrocarbons (ClPAHs), including polychlorinated naphthalenes (PCNs), are hazardous and widespread in the environment, but studies of these substances in the wastewater environment are lacking. In this study, five typical PCNs and five typical ClPAHs (other than PCNs) were simultaneously detected along with their parent polycyclic aromatic hydrocarbons in wastewater samples. All these compounds could be analyzed by gas chromatography- electron ionization mass spectrometry in selected ion monitoring mode and separated on a DB-17ms column. Calibration curves were created both in pure solvent and in wastewater matrix samples. The coefficients of determination for most compounds were greater than 0.99, indicating a satisfactory degree of linearity in the complex matrix samples. The influence of the matrix on the true concentrations of the environmental samples was corrected by use of the matrix calibration curve. The recoveries of all compounds were between 58% and 127%, with standard deviations lower than 20%. The method detection and quantification limits were less than 27.6 ng/L and less than 91.9 ng/L respectively in the aqueous phase, and less than 0.18 ng/L and less than 0.61 ng/L respectively in the solid phase of 4-L wastewater samples. This analytical method was successfully used to detect PCNs and ClPAHs in the water from a river receiving effluent from a wastewater treatment plant. The concentrations of each compound ranged from 3.1 to 29.6 ng/L. This method could also be used for detection of other polycyclic aromatic hydrocarbon derivatives with similar physical and chemical properties in different matrix samples. Graphical Abstract ᅟ.
More Related Videos
07:57Quantitative Detection of Trace Explosive Vapors by Programmed Temperature Desorption Gas Chromatography-Electron Capture Detector
Published on: July 25, 2014
04:39A Modified QuEChERS-HPLC Method for Detection of Polycyclic Aromatic Hydrocarbons in Zebrafish Embryos Exposed to Fine Particulate Matter
Published on: June 13, 2025
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Gas Chromatography: Types of Detectors-II
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...