Clinical Judgment Is Not Reliable for Reducing Whole-body Computed Tomography Scanning after Isolated High-energy
Thomas Mistral1, Vivien Brenckmann, Laurence Sanders
1From the Grenoble Alpes Trauma Center, Pôle Anesthésie-Réanimation, CHU Grenoble Alpes, Grenoble, France (T.M., J-F.P., P.B.); Université Grenoble Alpes, Grenoble, France (T.M., V.B., J-L.B., G.F., J-F.P., P.B.); INSERM U1216, Grenoble, France (T.M., J-F.P., P.B.); Département de Médecine d'Urgence, CHU Grenoble Alpes, Grenoble, France (V.B., L.S.); Pôle Recherche, CHU Grenoble Alpes, Grenoble, France (J-L.B.); Pole Imagerie, CHU Grenoble Alpes, Grenoble, France (G.F., F.T.); Divisions of Trauma Anesthesiology and Critical Care Medicine, Department of Anesthesiology, R Adams Cowley Shock Trauma Center, Baltimore, Maryland (S.M.G.).
Background:
The purpose of this study was to test the diagnostic performance of clinical judgment for the prediction of a significant injury with whole-body computed tomography scanning after high-energy trauma.
Methods:
The authors conducted an observational prospective study in a single level-I trauma center. Adult patients were included if they had an isolated high-energy injury. Senior trauma leaders were asked to make a clinical judgment regarding the likelihood of a significant injury before performance of a whole-body computed tomography scan. Clinical judgments were recorded using a probability diagnosis scale. The primary endpoint was the diagnosis of a serious-to-critical lesion on the whole-body computed tomography scan. Diagnostic performance was assessed using receiver operating characteristic analysis.
Results:
Of the 354 included patients, 127 patients (36%) had at least one injury classified as abbreviated injury score greater than or equal to 3. The area under the receiver operating characteristic curve of the clinical judgment to predict a serious-to-critical lesion was 0.70 (95% CI, 0.64 to 0.75%). The sensitivity of the clinical judgment was 82% (95% CI, 74 to 88%), and the specificity was 49% (95% CI, 42 to 55%). No patient with a strict negative clinical examination had a severe lesion (n = 19 patients). The sensitivity of the clinical examination was 100% (95% CI, 97 to 100%) and its specificity was 8% (95% CI, 5 to 13%).
Conclusions:
Clinical judgment alone is not sufficient to reduce whole-body computed tomography scan use. In patients with a strictly normal physical examination, whole-body computed tomography scanning might be avoided, but this result deserves additional study in larger and more diverse populations of trauma patients.
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography
Radiological Investigation I: X-ray and CT
Imaging Studies for Cardiovascular System V: CT

![Semi-quantitative Assessment Using [18F]FDG Tracer in Patients with Severe Brain Injury](/_next/image?url=https%3A%2F%2Fcloudfront.jove.com%2FCDNSource%2Fteasers%2F58641.jpg&w=3840&q=50)
