Preparation and application of covalently bonded polysaccharide-modified stationary phase for per aqueous liquid
Tong Chen1, Ling Zhu2, Huiyuan Lu3
1State Key Laboratory of Food Additive and Condiment Testing, Zhenjiang Entry-exit Inspection Quarantine Bureau, Zhenjiang 212008, China.
Abstract:
The mixed phosphorylated/methacryloyl polysaccharide derivative was prepared and immobilized onto porous silica surface through the radical polymerization. The successful immobilization of polysaccharide on the silica support was confirmed by FT-IR spectra, elemental analysis and transmission electron microscopy (TEM), and so on. The new stationary phase (MCPP-SP) showed both hydrophilic interaction liquid chromatography (HILIC) and per aqueous liquid chromatography (PALC) characteristics. The chromatographic behaviors were evaluated by investigating the effects of water content, column temperature, mobile phase pH and salt concentration, and a typical PALC retention feature of MCPP-SP based column was observed at high percentage of water content. Compared with C18 column, using MCPP-SP column, separation of polar compounds including synthetic pigments and sulfa compounds in the PALC mode was successfully accomplished. The results demonstrated that MCPP-SP column exhibited stronger retention efficiency for various polar compounds. PALC as a green chromatography analytical method was suitable for the replacement of HILIC.
More Related Videos
07:20Activation and Conjugation of Soluble Polysaccharides using 1-Cyano-4-Dimethylaminopyridine Tetrafluoroborate CDAP
Published on: June 14, 2021
10:27Preparation of Highly Porous Coordination Polymer Coatings on Macroporous Polymer Monoliths for Enhanced Enrichment of Phosphopeptides
Published on: July 14, 2015
Related Concept Videos
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
Analyte Adsorption and Distribution
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
Silica Gel Column Chromatography: Overview
Polar components tend to bind strongly to the silica gel, causing them to move slowly through the column. In contrast, nonpolar compounds...
Ion-Exchange Chromatography
Ion Exchange