Fixed-dose combination orally disintegrating tablets to treat cardiovascular disease: formulation, in vitro
Thomas J Dennison1, Julian C Smith2, Raj K Badhan1
1Aston School of Pharmacy, Aston University, Birmingham.
Insights
Fixed-dose combination orally disintegrating tablets (ODTs) of amlodipine and atorvastatin demonstrated bioequivalence. This fixed-dose combination ODT offers a promising approach for managing hypertension and dyslipidemia, improving patient compliance.
Area of Science:
- Pharmaceutical Technology
- Pharmacokinetics
- Drug Formulation
Background:
- Cardiovascular disease (CVD) management often requires coadministration of amlodipine for hypertension and atorvastatin for dyslipidemia.
- Fixed-dose combination (FDC) oral dosage forms and orally disintegrating tablet (ODT) technology can potentially improve patient compliance and therapeutic outcomes.
Purpose of the Study:
- To develop and characterize single and FDC ODTs containing amlodipine and atorvastatin.
- To compare the bioequivalence of these single and FDC formulations using in vitro and in silico methods.
Main Methods:
- Development and characterization of amlodipine/atorvastatin single and FDC ODTs.
- In vitro dissolution testing in simulated intestinal fluids.
- Caco-2 cell apparent permeability (Papp) assessment.
- In silico physiologically based pharmacokinetic (PBPK) modeling and simulation.
Main Results:
- Single and FDC ODTs exhibited rapid disintegration (<30 s), high crushing strength (>100 N), and low friability (≤1%).
- In vitro dissolution profiles were comparable between single and FDC ODTs, except for amlodipine in fed-state simulated intestinal fluid.
- Pharmacokinetic simulations indicated no significant difference in bioavailability between single and combination doses, confirming bioequivalence.
Conclusions:
- The developed FDC ODT formulation for amlodipine and atorvastatin is bioequivalent to their individual formulations.
- Mechanistic pharmacokinetic modeling offers a robust approach for assessing oral drug absorption and bioequivalence, complementing traditional in vitro methods.
Abstract:
Cardiovascular disease (CVD) is the leading cause of death among men and women worldwide. In CVD, hypertension and dyslipidemia commonly coexist and are managed through coadministration of amlodipine and atorvastatin, respectively. The case for fixed-dose combination (FDC) oral dosage forms and orally disintegrating tablet (ODT) technology to enhance outcomes and compliance is strong. This work follows the development and characterization of single and FDC ODTs containing amlodipine and atorvastatin, followed by bioequivalence comparison between these single and FDC formulations, using in vitro dissolution and Caco-2 apparent permeability (Papp) and in silico physiologically based pharmacokinetic modeling approaches. ODTs containing amlodipine (5 mg) and atorvastatin (10 mg) either alone or in combination rapidly disintegrated (<30 s) while displaying a radial crushing strength in excess of 100 N and friability ≤1%. In vitro dissolution test was performed in fasted and fed-state simulated intestinal fluid (FeSSIF) and analyzed using high-performance liquid chromatography. Dissolution profiles for single and FDC ODTs were compared using US FDA recommended difference (f1) and similarity (f2) factor testing for bioequivalence. In all cases, there was no difference in active pharmaceutical ingredient dissolution between single or FDC ODTs, with the exception of amlodipine in FeSSIF. Pharmacokinetic clinical trial simulations were conducted using Simcyp (Version 14), incorporating Papp and dissolution data. Simulated clinical trials in healthy volunteers showed no difference in bioavailability based on pharmacokinetic parameters between single and combination doses with either active pharmaceutical ingredient. An increase in Cmax and AUC for atorvastatin in fed subjects was attributed to extended transit along the gut lumen and reduced atorvastatin metabolism due to lower CYP3A4 expression at more distal small intestine absorption sites. The results demonstrated bioequivalence of an FDC ODT for amlodipine and atorvastatin, while highlighting several limitations of f1 and f2 bioequivalence testing and strengths of mechanistic pharmacokinetic modeling for oral drug absorption.
Related Concept Videos
In Vitro Drug Dissolution: Compendial Testing Models I
Drug Product Performance: In Vitro–In Vivo Correlation
Impact of Pharmacokinetic–Pharmacodynamic Models: Regulatory Decisions
In Vitro Drug Dissolution: Compendial Testing Models II
Modified-Release Drug Delivery Systems: Bioavailability
Oral Drug Delivery Systems: Continuous-Release Systems