Related Experiment Video
Updated: Aug 2, 2026

Echocardiographic Assessment of Cardiac Anatomy and Function in Adult Rats
Published on: December 13, 2019
Echocardiographic right ventricular function correlations with cardiac catheterisation data in biventricular
Holly Nadorlik1, Corey Stiver1, Sairah Khan1
1Heart Center, Nationwide Children's Hospital,Columbus,Ohio,United States of America.
Background:
Newer echocardiographic techniques may allow for more accurate assessment of right ventricular function. Adult studies have correlated these echocardiographic measurements with invasive data, but minimal data exist in the paediatric congenital heart population. The purpose of this study was to evaluate echocardiographic measurements that correlate best with right ventricular systolic and diastolic catheterisation parameters.
Methods:
Patients with two-ventricle physiology who underwent simultaneous echocardiogram and cardiac catheterisation were included in this study. Right ventricular systolic echocardiographic data included fractional area change, displacement, tissue Doppler imaging s' wave, global longitudinal strain, and strain rate s' wave. Diastolic echocardiographic data included tricuspid E and A waves, tissue Doppler imaging e' and a' waves, and strain rate e' and a' waves. E/tissue Doppler imaging e', tissue Doppler imaging e'/tissue Doppler imaging a', E/strain rate e', and strain rate e'/strain rate a' ratios were also calculated. Catheterisation dP/dt was used as a marker for systolic function and right ventricular end-diastolic pressure for diastolic function.
Results:
A total of 32 patients were included in this study. The median age at catheterisation was 3.1 years (0.3-17.6 years). The DP/dt was 493±327 mmHg/second, and the right ventricular end-diastolic pressure was 7.7±2.4 mmHg. There were no significant correlations between catheterisation dP/dt and systolic echocardiographic parameters. Right ventricular end-diastolic pressure correlated significantly with strain rate e' (r=-0.4, p=0.02), strain rate a' (r=-0.5, p=0.03), and E/tissue Doppler imaging e' (r=0.4, p=0.04).
Conclusion:
Catheterisation dP/dt did not correlate with echocardiographic measurements of right ventricular systolic function. Strain rate and tissue Doppler imaging analysis significantly correlated with right ventricular end-diastolic pressure. These values should be further studied to determine whether they may be used as an alternative method to estimate right ventricular end-diastolic pressure in this patient population.
Related Concept Videos
Imaging Studies for Cardiovascular System I:Echocardiography
Indications: Echocardiography is utilized to diagnose heart failure, valve disorders, and myocardial infarction. It also assesses cardiac structures' size, shape, and motion, evaluates...
Cardiac Catheterization II: Right Heart Catheterization
Cardiac Catheterization III: Left Heart Catheterization

