Related Experiment Video
Updated: Aug 19, 2026

Observational Study Protocol for Repeated Clinical Examination and Critical Care Ultrasonography Within the Simple Intensive Care Studies
Published on: January 16, 2019
Evaluation of Carotid Ultrasonography Screening Among Kidney Transplant Candidates: A Single-Center, Retrospective
Chad W Rossitter1, Ronald B Vigo1, Ahmed Osama Gaber1
1J. C. Walter Jr. Transplant Center and the Nephrology Program, Department of Medicine, Houston Methodist Hospital, Houston, TX.
Background:
Kidney transplant candidates undergo rigorous testing prior to clearance for transplantation. Because kidney transplant candidates may be at increased risk for carotid artery stenosis because of arteriosclerosis and atherosclerosis secondary to hypertension, vascular calcification, and diabetes, carotid ultrasound is often performed with the intent of preventing a cerebrovascular accident in the perioperative or posttransplant period. To our knowledge, there has not been a study investigating the utility of screening carotid ultrasonography in pretransplant candidates. The purpose of the present study was to investigate the yield of carotid ultrasonography in end-stage renal disease patients, at high risk for having clinically significant vascular disease evaluated at our center for kidney transplantation during the years 2009 to 2014.
Methods:
Data for carotid ultrasound findings and risk factors for carotid artery disease were extracted from the medical records.
Results:
A total of 882 patients were included in our study of which only 13 patients (1.47% of the cohort) had significant carotid artery stenosis (>70%) on ultrasound testing. Using multiple logistic regression on the outcome of carotid stenosis, congestive heart failure (adjusted odds ratio, 5.2), and peripheral vascular disease (adjusted odds ratio, 4.4) were positively associated with carotid stenosis.
Conclusions:
The prevalence of significant carotid artery stenosis was only 1.47% in our cohort of kidney transplant candidates, and the routine use of carotid ultrasound testing in this population may not be an efficient use of clinical resources. Use of risk factors, such as congestive heart failure or peripheral vascular disease, may identify patients who are more likely to benefit from carotid ultrasonography screening.
Related Concept Videos
Kidney Transplant I: Introduction
Kidney Transplant II: Surgical Procedure
Kidney Transplant III: Nursing Management
Imaging Studies II: Ultrasonography
Imaging Studies III: Computed Tomography
Imaging Studies VII: Vascular Imaging