Related Experiment Video
Updated: Jul 25, 2026

Automated Hydrophobic Interaction Chromatography Column Selection for Use in Protein Purification
Published on: September 21, 2011
Evaluation of several protein a resins for application to multicolumn chromatography for the rapid purification of
Nicolas-Julian Hilbold1,2, Xavier Le Saoût3, Eric Valery1
1Novasep Process SAS, Nancy, France.
Abstract:
Most of the existing production capacity is based on fed-batch bioreactors. Thanks to the development of more efficient cell lines and the development of high-performance culture media, cell productivity dramatically increased. In a manufacturing perspective, it is necessary to clear as quickly as possible the protein A capture step to respect the manufacturing agenda. This article describes the methodology applied for the design of a multicolumn chromatography process with the objective of purifying as quickly as possible 1,000 and 15,000 L fed-batch bioreactors. Several recent and reference protein A resins are compared based on characteristic values obtained from breakthrough curves. The importance and relevance of resin parameters are explained, and purposely simple indicators are proposed to quickly evaluate the potential of each candidate. Based on simulation data, the optimum BioSC systems associated with each resin are then compared. The quality of the elution delivered by each resin is also compared to complete the assessment. © 2017 American Institute of Chemical Engineers Biotechnol. Prog., 33:941-953, 2017.
Related Concept Videos
Principles Of Column Chromatography
Types Of Column Chromatography
Gel Filtration Chromatography
When the...
Affinity Chromatography