Related Experiment Video
Updated: Aug 4, 2026

Contrast Enhanced Ultrasound Imaging for Assessment of Spinal Cord Blood Flow in Experimental Spinal Cord Injury
Published on: May 7, 2015
The effect of blood volume and volume loading on left ventricular diastolic function in individuals with spinal cord
H Sharif1,2, L Wainman1,2, D O'Leary2,3
1Department of Kinesiology, Brock University, St Catharines, ON, Canada.
Study Design:
Cohort Study (Prospective Observational Study).
Objectives:
The objectives of the study were (i) to examine left ventricular (LV) diastolic function at rest and during rapid saline infusion in those with spinal cord injury (SCI) and (ii) to determine the contribution of blood volume on the purported diastolic impairments in individuals with SCI.
Settings:
St Catharines, ON, Canada.
Methods:
Thirteen SCI (AIS:A-D; C4-T6; age: 41±8.5; 10 males, 3 females) and 12 able-bodied (AB) individuals (age: 40±8.5; 9 males, 3 females) without a history of cardiovascular disease participated in the study. LV structure and diastolic function were assessed via conventional echocardiography. The carbon monoxide rebreathe test was used to measure the blood volume. LV diastolic function was assessed once more following rapid saline infusion (dose: 15 ml kg-1; rate: 100 ml min-1).
Results:
Compared with the AB group, individuals with SCI had a smaller LV internal diameter (SCI: 4.5±0.3 cm vs AB: 5.1±0.7 cm; P=0.01), lower blood volume (SCI: 3.9±0.6 l vs AB: 5.0±1.2 l; P=0.02) and end-diastolic volume (SCI: 97.2±29.4 ml vs AB: 128.6±38.3 ml; P=0.03). There were no between-group differences in baseline diastolic parameters; however, when LV internal diameter was adjusted for individuals with SCI demonstrated lower early to late transmitral velocity ratio (SCI: 1.9±0.5 vs AB: 2.2±0.7; P=0.03). There was no between-group difference in diastolic responses to the saline infusion, as both groups showed similar diastolic changes following volume loading.
Conclusion:
Individuals with SCI have preserved LV diastolic function despite having lower preload. Preserved diastolic function may be mediated by the cardiac atrophy that occurs following SCI. Individuals with SCI also demonstrate normal diastolic responses to increased volume loading, suggesting compliant ventricles.
More Related Videos
Related Concept Videos
Cardiac Output and Stroke Volume
In an average resting adult male, the typical cardiac output averages...
Regulation of Stroke Volume
Preload refers to the degree of stretch on the heart before it contracts. It's analogous to the stretching of a rubber band; the more it's stretched, the more forcefully it snaps back. This concept is encapsulated in the Frank-Starling law of the...
Imbalances in Cardiac Output
CHF can occur due to the failure of either side of the heart. Left-side failure leads to pulmonary congestion—the right side continues to send blood...
Cardiac Output II: Effect of Stroke Volume on Cardiac Output
Preload
Preload refers to the initial elongation of the cardiac myocytes before contraction and is related to the volume of blood filling the heart at the end of diastole, or end-diastolic volume. The...
Heart Failure II: Pathophysiology
Spinal Cord Injury ll: Pathophysiology

