EFFECT OF BODY POSITION ON INTRAOCULAR PRESSURE IN SILICONE OIL TAMPONADE EYES
Related Experiment Video
Updated: Oct 2, 2026

Trabecular Meshwork Response to Pressure Elevation in the Living Human Eye
Published on: June 20, 2015
Jiandong Pan1, Dan Cheng1, Xiaofen Feng1
1School of Optometry and Ophthalmology, Eye Hospital, Wenzhou Medical University, Wenzhou, Zhejiang, China.
Purpose:
To investigate the effect of body position on intraocular pressure (IOP) in silicone oil tamponade eyes.
Methods:
This prospective study included 18 eyes from 18 silicone oil tamponade patients and 24 eyes from 24 healthy subjects. Intraocular pressures were measured by Accupen Applanation Tonometer sitting with face forward, sitting with face down, supine, nondependent lateral decubitus, dependent lateral decubitus, and prone positions. The IOPs in each position and the magnitudes of IOP change were compared between the silicone oil and normal groups.
Results:
In both groups, the IOPs in sitting positions were significantly lower than that of each recumbent position. The IOPs were highest in prone among all positions. No significant difference was found between IOPs of each group in each position. Between both groups, the IOP elevations in each position had no statistical difference compared with sitting with face forward.
Conclusion:
The IOP is lowest in the sitting position and highest in the prone position in both silicone oil and normal groups. Between both groups, the amount of IOP elevations is equivalent in each position compared with sitting with face forward. Ophthalmologists should be aware that IOP is higher in the prone position and that it should be monitored accordingly.
Related Concept Videos
Glaucoma: Overview
Open Angle Glaucoma: Treatment
Drugs such as carbonic anhydrase inhibitors, α2- and...
Angle Closure Glaucoma: Treatment
Ophthalmic Drug Delivery Systems
Increased Intracranial Pressure l: Introduction