NIST Standard Reference Material 3600: Absolute Intensity Calibration Standard for Small-Angle X-ray Scattering
Andrew J Allen1, Fan Zhang1, R Joseph Kline2
1Materials Measurement Science Division, National Institute of Standards and Technology , 100 Bureau Drive, Gaithersburg, MD 20899, USA.
Summary
A new standard reference material (SRM 3600) for small-angle X-ray scattering (SAXS) intensity calibration has been certified. This glassy carbon standard ensures accurate and universal SAXS instrument calibration across various X-ray energies.
Area of Science:
- Materials Science
- Analytical Chemistry
- Physics
Background:
- Accurate intensity calibration is crucial for quantitative analysis in small-angle X-ray scattering (SAXS).
- Existing calibration methods can be instrument-specific and lack universal applicability.
- A need exists for a stable, robust standard reference material for SAXS intensity calibration.
Purpose of the Study:
- To present the certification of NIST Standard Reference Material (SRM) 3600, an absolute intensity calibration standard for SAXS.
- To describe the methodology for achieving and validating the intensity calibration of the SRM.
- To outline the intended use, availability, and universal applicability of the new SAXS standard.
Main Methods:
- Development of SRM 3600 based on glassy carbon, leveraging ultra-small-angle X-ray scattering (USAXS) primary calibration capabilities.
- Intensity calibration achieved and validated within the certified Q range of 0.008–0.25 Å⁻¹.
- Validation of SAXS intensity calibration using small-angle neutron scattering (SANS) techniques.
Main Results:
- Successful certification of SRM 3600 as an absolute intensity calibration standard for SAXS.
- Demonstrated universal applicability of the SRM for SAXS instruments with transmission geometry across diverse X-ray energies/wavelengths.
- Validation of the SRM's SAXS intensity calibration using SANS, with potential for future SANS inclusion.
Conclusions:
- NIST SRM 3600 provides a reliable and universally applicable standard for SAXS absolute intensity calibration.
- The SRM enhances the accuracy and comparability of SAXS data across different instruments and laboratories.
- Future work may extend the SRM's utility to include small-angle neutron scattering calibration.
Related Concept Videos
X-ray Diffraction of Biological Samples
X-ray diffraction or XRD is an analytical tool that utilizes X-rays to study ordered structures such as crystalline organic and inorganic samples, polycrystalline materials, proteins, carbohydrates, and drugs.
According to Bragg's law, when X-rays strike the sample positioned on a stage, the rays are scattered by the electron clouds around the sample atoms. The X-ray diffraction or scattering is caused by constructive interference of the X-ray waves that reflect off the internal crystal...
According to Bragg's law, when X-rays strike the sample positioned on a stage, the rays are scattered by the electron clouds around the sample atoms. The X-ray diffraction or scattering is caused by constructive interference of the X-ray waves that reflect off the internal crystal...
Atomic Absorption Spectroscopy: Lab
For AAS measurements, samples must be introduced as clear solutions, often requiring extensive preliminary treatment to dissolve materials like soils, animal tissues, and minerals. Common methods for sample preparation include treatment with hot mineral acids, wet ashing, combustion in closed containers, high-temperature ashing, or fusion with reagents.
Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing nebulizer...
Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing nebulizer...