Related Experiment Video
Updated: Jun 8, 2026

Procedure to Evaluate the Efficiency of Flocculants for the Removal of Dispersed Particles from Plant Extracts
Published on: April 9, 2016
The relationship between extent of hemoglobin purification and the performance characteristics of a blood-based
Rafael A Garcia1, Lorelie P Bumanlag1, George J Piazza1
1Biobased and Other Animal Co-products Research Unit, Eastern Regional Research Center, ARS, USDA, Wyndmoor, PA, USA.
Background:
Whole blood is a highly complex substance. Hemoglobin, the most abundant blood protein, can function as a flocculant; most of the other blood components exhibit poor flocculant activity. For the purpose of processing raw whole blood into a flocculant product, the practical value of hemoglobin purification is uncertain.
Results:
This study compares the flocculant performance of whole blood to that of three different semi-purified hemoglobin preparations. The whole blood is processed to remove the plasma proteins, the solid cell components, or both. The flocculant performance of whole blood and each hemoglobin preparation is compared over wide ranges of flocculant dose and suspension pH. The clarified liquids are examined for increases in chemical oxygen demand and Kjeldahl nitrogen. Hemoglobin preparations that excluded plasma gave peak flocculation performance at approximately 30 mg solids per gram of suspended kaolin, and gave greatly reduced performance at higher doses; preparations that included plasma gave very similar peak performance, but also maintained relatively high performance at doses up to at least 200 mg g-1 .
Conclusion:
It is shown that removal of the plasma and the cell solids does not improve the flocculant performance or lessen the residual pollutants in the treated water. Published 2017. This article is a U.S. Government work and is in the public domain in the USA.
Related Concept Videos
Colloidal precipitates
Filtration
Centrifugation
Coagulation
Optimizing Chromatographic Separations
Band broadening refers to spreading solute bands as they travel through the column. This broadening can impact resolution. Plate height (H) represents the length required for one theoretical plate. A lower plate height corresponds to...
Extracorporeal Removal of Drugs: Hemoperfusion and Hemofiltration