Related Experiment Video
Updated: Jul 19, 2026

Combining Volumetric Capnography And Barometric Plethysmography To Measure The Lung Structure-function Relationship
Published on: January 8, 2019
Are Predictive Energy Expenditure Equations in Ventilated Surgery Patients Accurate?
Christopher J Tignanelli1, Allan G Andrews2, Kurt M Sieloff1
11 Division of Acute Care Surgery (Trauma, Burns, Critical Care, Emergency Surgery), Department of Surgery, University of Michigan, Ann Arbor, MI, USA.
Predictive equations for estimating resting energy expenditure (REE) are inaccurate in surgical intensive care unit (SICU) patients. Indirect calorimetry (IC) is recommended for precise calorie needs in critically ill patients.
Area of Science:
- Critical Care Medicine
- Nutritional Support
- Metabolic Monitoring
Background:
- Indirect calorimetry (IC) is the gold standard for determining calorie needs in critically ill patients.
- Predictive equations are often used but may misjudge resting energy expenditure (REE) in medical and mixed ICUs.
- The accuracy of these equations in surgical ICUs (SICUs) remains under-evaluated.
Purpose of the Study:
- To compare REE measured by IC with REE calculated using predictive equations and calorie goals in ventilated adult SICU patients.
- To evaluate the utility of common predictive methods for nutritional support in SICU settings.
Main Methods:
- Retrospective review of prospectively collected data from 419 mechanically ventilated adult SICU patients.
- Estimated REE using Harris-Benedict equations (HBEs) and fixed calorie goals (20, 25, 30 kcal/kg/d) with actual, adjusted, and ideal body weights.
- Measured REE using indirect calorimetry (IC).
Main Results:
- Predictive equations (HBE, 20, 25, 30 kcal/kg/d) were inaccurate for estimating REE in SICU patients, regardless of patient characteristics.
- HBE and 20 kcal/kg/d underestimated REE, while 25 and 30 kcal/kg/d overestimated it.
- Harris-Benedict equations using actual body weight (35% accuracy) and 25 kcal/kg/d adjusted body weight (34% accuracy) were the most accurate, but still imprecise.
Conclusions:
- Established predictive equations and fixed calorie goals are unreliable for determining daily caloric requirements in critically ill SICU patients.
- Indirect calorimetry (IC) measurement is crucial for accurate REE determination to guide nutritional support in SICU patients.
- Accurate caloric assessment is essential for patient recovery in the SICU.
Related Concept Videos
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Factors Affecting Pulmonary Ventilation
Alveolar Surface Tension
The alveolar fluid lines the luminal surface of the alveoli and exerts a force called surface tension. This force is caused by the polar water molecules in the liquid being more strongly attracted to each...
Respiratory Volumes and Capacities