Comparison of gray values of cone-beam computed tomography with hounsfield units of multislice computed tomography:
Sanjana Patrick1, N Praveen Birur1, Keerthi Gurushanth1
1Department of Oral Medicine and Radiology, KLE Society's Institute of Dental Sciences, Bengaluru, Karnataka, India.
Purpose:
Hounsfield unit (HU) provides a quantitative evaluation of bone density. The assessment of bone density is essential for successful treatment plan. Although, multislice computed tomography (MSCT) is considered as gold standard in evaluating bone density, cone-beam computed tomography (CBCT) is frequently used in dentomaxillofacial imaging due to lower radiation dose, less complex device, and images with satisfactory resolution.
Aims And Objectives:
The aim of this study is to determine and compare the gray value and HU value of hypodense and hyperdense structures on CBCT and MSCT, respectively. The study also evaluated and compared the gray values in different field of views within CBCT.
Materials And Methods:
A total of 20 dry human mandibles were obtained. The gray values and HU values of hypodense structures (extraction socket, inferior alveolar canal, and mental foramen) and hyperdense structures (enamel, cancellous, and cortical bone) were evaluated and compared between CBCT and MSCT images, respectively. The obtained data were statistically analyzed.
Statistical Analysis:
One-way analyses of variance, ANOVA F-test.
Results:
The gray value for hypodense structures in large volume CBCT scans resembled the HU value. The study showed statistically significant difference (P < 0.001) in gray values for all the hyperdense structures in CBCT when compared to HU values of MSCT scans.
Conclusion:
The gray value for hypodense structures in large volume CBCT scan was more reliable and analogous to HU value in MSCT. The determination of grey values in CBCT may not be as accurate as HU value in CT for hyperdense structures.
More Related Videos
06:33Construction of a Preclinical Multimodality Phantom Using Tissue-mimicking Materials for Quality Assurance in Tumor Size Measurement
Published on: July 29, 2013
08:13In Vivo Quantitative Assessment of Myocardial Structure, Function, Perfusion and Viability Using Cardiac Micro-computed Tomography
Published on: February 16, 2016
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies for Cardiovascular System V: CT