Related Experiment Video
Updated: Jun 29, 2026

Spatial Measurements of Perfusion, Interstitial Fluid Pressure and Liposomes Accumulation in Solid Tumors
Published on: August 18, 2016
Evaluation of radiolabeled curcumin-loaded solid lipid nanoparticles usage as an imaging agent in liver-spleen
Arif Kursad Ayan1, Ayse Yenilmez2, Hayrettin Eroglu3
1Department of Nuclear Medicine, Ataturk University, 25240 Erzurum, Turkey.
Abstract:
Curcumin-loaded solid lipid nanoparticles (C-SLNs) were prepared using micro emulsion and ultrasonication methods in the first stage of this study to determine the role of C-SLN on liver-spleen scintigraphy. It was concluded that the curcumin that was encapsulated in solid lipid nanoparticles had a β' polymorph structure according to the X-ray diffraction (XRD) analysis. İt was concluded that these particles were at nano scale according to the laser diffraction (LD) analysis. Fourier transform infrared spectroscopy (FT-IR) analysis suggested an interaction between the curcumin and the solid lipid matrix, and the curcumin was loaded on the solid lipid nanoparticles. Moreover, the particles were concluded to be spherical and at nanoscale according to the scanning electron microscopy (SEM) and transmission electron microscopy (TEM) images. On the other hand, thermogravimetric analysis (TGA) suggested that the curcumin loaded solid nanoparticles were stable against the temperature. C-SLNs were labeled with Technetium-99m (99mTc) radioisotope in the second stage of the study, then using scintigraphic methods in-vivo studies were performed on New Zealand rabbit and made a comparison with Phytate colloid, routinely used in liver-spleen scintigraphy. After analyzing the images and the biological distributions obtained from the experiments, uptake was observed in the liver and the spleen. Following from the experiment results, 99mTc-labeled C-SLNs was concluded to be a possible imaging agent. In particular, it could be a new radiopharmaceutical alternative to 99mTc-labeled compounds that are used in liver and spleen imaging in colloid scintigraphy.
Related Concept Videos
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET