Two-dimensional gas chromatography with electron capture detection for the analysis of atmospheric ozone depleting
Chang-Feng Ou-Yang1, Hsi-Che Hua2, Yu-Chieh Chou2
1Department of Atmospheric Sciences, National Central University, Taoyuan 32001, Taiwan.
Abstract:
This study is to develop a GC×GC method with electron capture detection (ECD) to analyze atmospheric halocarbons in the concentration range of parts per trillion by volume (pptv). To enrich atmospheric halocarbons a home-built thermal desorption (TD) device was coupled to the GC×GC-ECD. The technique of flow modulation was adopted using a Deans switch for GC×GC. Several column combinations of first and second dimensions were tested and the column set of DB-5×TG-1301 was found to show the best orthogonality for halocarbons. A series of modulation parameters were tested for their optimal settings. The modulation period (PM) was found to have minimal wrap-around when set at 3s. The modulation ratio (MR) was determined to be 7.82 to ensure reproducible results and maximum sensitivity. The modulation duty cycle (DC) was calculated to be approximately 0.17. Nine halocarbons were separated successfully and seven were calibrated with the use of a certified standard gas mixture. The correlation coefficients (R2) were greater than 0.9972. The reproducibility was better than 1.90% as expressed in relative standard deviation (RSD; N=30) and the detection limits were in the range of pptv for the target halocarbons. A field test by continuous analyzing ambient air with hourly resolution was performed to show the stability of the method as suggested by the homogeneity of certain halocarbons, while also reflecting concentration variation for others when emissions did arise.
More Related Videos
10:14Chromatographic Fingerprinting by Template Matching for Data Collected by Comprehensive Two-Dimensional Gas Chromatography
Published on: September 2, 2020
11:44Qualitative Characterization of the Aqueous Fraction from Hydrothermal Liquefaction of Algae Using 2D Gas Chromatography with Time-of-flight Mass Spectrometry
Published on: March 6, 2016
Related Concept Videos
Gas Chromatography: Types of Detectors-II
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Gas Chromatography: Sample Injection Systems
Two primary injection methods are used...