Related Experiment Video
Updated: Jun 2, 2026

Murine Renal Transplantation Procedure
Published on: July 10, 2009
Effect of urine creatinine level during pregnancy on dipstick test
Yosuke Baba1, Itsuko Furuta2, Tianyue Zhai2
1Department of Obstetrics and Gynecology, Jichi Medical University Hospital, Shimotsuke, Japan.
Aim:
Dipstick results for proteinuria are affected by urine concentration, and thus urine creatinine concentration ([Cr]). This study was performed to determine whether spot urine [Cr] changes significantly during pregnancy, leading to a significantly different false-negative rate (FNR) on dipstick test between trimester.
Methods:
The [Cr] and protein concentrations ([P]) were analyzed in 631 spot urine samples with negative/equivocal dipstick from 425 pregnant women. False-negative dipstick was defined as [P] : [Cr] ratio (P/Cr) > 0.27 mg/mg.
Results:
Median [Cr] was 117 mg/dL (range, 6.5-326 mg/dL), 72 mg/dL (range, 4.3-477 mg/dL), and 73 mg/dL (range, 8.4-396 mg/dL) in the first (n = 96), second (n = 344), and third (n = 191) trimester urine samples, respectively (P = 0.000, Kruskal-Wallis). Both [P] and P/Cr increased significantly with advancing gestation. FNR 9.4% (18/191) in the third trimester was significantly higher than that of 0.0% (0/96) in the second trimester and that of 0.5% (2/344) in the third trimester. In the 20 urine samples with false-negative dipstick, median [Cr] was 47.0 mg/dL (range, 11.0-358 mg/dL) and the proportion of samples with dilute urine, that is, [Cr] <47 mg/dL, was significantly higher than in the remaining 611 urine samples (50%, 10/20 vs 28%, 174/611, respectively, P = 0.046).
Conclusions:
Urine samples in the second and third trimesters were more likely to be diluted compared with the first trimester. This was associated with high FNR in third trimester urine samples.
Related Concept Videos
Factors Affecting Renal Clearance: Renal Impairment
One condition associated with renal failure is uremia. Uremia is characterized by impaired glomerular filtration and fluid accumulation in the body. This condition hinders the renal clearance of drugs, resulting in drug accumulation and potential...
Drug Dosing in Renal Diseases: Measurement of Glomerular Filtration Rate
Drug Dosing in Renal Diseases: Measurement of Serum Creatinine Concentration and Clearance
Drug Dosing in Renal Diseases: Estimation of Glomerular Filtration Rate Based on Serum Creatinine Concentration
Urine Studies I: Urinalysis
Serum Studies: Renal Function Tests