Related Experiment Video
Updated: Mar 4, 2026

Semiconductor Sequencing for Preimplantation Genetic Testing for Aneuploidy
Published on: August 25, 2019
Pregnancy-associated plasma protein-A truncation limits in antenatal screening for trisomy 18
J P Bestwick1, W J Huttly1, N J Wald1
1Wolfson Institute of Preventive Medicine, Barts and The London School of Medicine and Dentistry, Queen Mary University of London, London, UK.
Abstract:
Upper and lower truncation limits are commonly applied to quantitative markers used in medical screening tests. We here examine data on 375 trisomy 18 and 522,081 unaffected singleton pregnancies, to determine if the lower truncation limit should be set below the previously specified 0.2 multiples of the median. A lower truncation limit of 0.15 would reduce the underestimation of the risk of having a trisomy 18 pregnancy in about 50% of affected pregnancies and would lead to an estimated 10 percentage point increase in the detection rate, with only a very small increase in the false-positive rate.