Related Experiment Video
Updated: Mar 3, 2026

Measurement of X-ray Beam Coherence along Multiple Directions Using 2-D Checkerboard Phase Grating
Published on: October 11, 2016
Impact of partial coherence on the apparent optical transfer function derived from the response to amplitude edges
Abstract:
We present an investigation of the impact of partial coherence on optical imaging systems with the focus on whole slide imaging (WSI) systems for digital pathology. The investigation is based on the analysis of the edge response of the optical system, which gives rise to an apparent optical transfer function (OTF) that can be linked to two elementary complex functions Q and U. The function Q is directly related to the transmission cross coefficient (TCC) and can be identified with the performance function first introduced by Kintner and Sillitto. The function U depends on the TCC in a more involved way. When there are no aberrations the Q-function corresponds to the real part of the apparent OTF and the U function to the imaginary part of the apparent OTF. Close to the incoherent limit the effect of the U function is a mere shift of the edge compared to the fully incoherent case. We propose a new expression for the dependence of the depth of focus (DOF) on spatial frequency and on the partial coherence factor σ, and validate it by simulation. Partial coherence effects are investigated experimentally on a WSI system with a compact LED-based Köhler illumination unit with variable condenser NA. This unit incorporates a top hat diffuser for providing a reasonably uniform illumination field, with variations below 10% across the imaged field of view. The measurements of the apparent through-focus OTF derived from edges on a custom resolution chart for different σ were substantially in agreement with the simulations. Finding an optimal value for σ is not straightforward as lateral resolution and the level of edge ringing improve with increasing σ, whereas edge contrast and DOF improve with decreasing σ. We assess that the trade-off for the particular application of WSI systems for digital pathology is optimized for a σ value in the range of 0.55-0.75.
More Related Videos
05:59Author Spotlight: Unlocking New Insights in fNIRS Studies - A Novel Framework for Inter-Brain Synchrony Analysis
Published on: October 6, 2023
08:25Combined Invasive Subcortical and Non-invasive Surface Neurophysiological Recordings for the Assessment of Cognitive and Emotional Functions in Humans
Published on: May 19, 2016
Related Concept Videos
IR Spectrum Peak Splitting: Symmetric vs Asymmetric Vibrations
Interference and Diffraction
Effective Value of a Periodic Waveform
The effective value of a periodic current represents the direct current (DC) that conveys the same average power to a resistor as the periodic current itself. This concept is crucial when assessing AC circuits. To determine the...
Transfer function and Bode Plots-II
Properties of Fourier Transform II
The Frequency Shifting property of Fourier Transforms highlights that a shift in the frequency domain corresponds to a phase shift in the time domain. Mathematically, if x(t) has...
Potential Due to a Polarized Object