Related Experiment Video
Updated: Mar 3, 2026

Computed Tomography (CT) Guided Implantation of a Totally Implantable Venous Access Port (TIVAP) through Subclavian Vein
Published on: January 13, 2026
Successful balloon assisted percutaneous thrombin injection of right subclavian artery pseudoaneurysm
Andrew D Brown1, Dhruvin H Hirpara2, Arash Jaberi1
1Division of Vascular and Interventional Radiology, Department of Medical Imaging, Toronto General Hospital-University Health Network/University of Toronto, Toronto - Canada.
Purpose:
To report the use of a balloon catheter to facilitate percutaneous ultrasound-guided thrombin injection of a subclavian artery pseudoaneurysm.
Case Report:
A 36-year-old man presented with hoarseness after the insertion of a right temporary internal jugular line. Arteriography showed a short neck right subclavian artery pseudoaneurysm. A 6 mm × 40 mm balloon catheter was positioned across the neck of the pseudoaneurysm to permit percutaneous ultrasound-guided thrombin injection. Immediate post-treatment angiogram demonstrated no filling of the pseudoaneurysm. Seven-month clinical and imaging follow-up confirmed resolution of the pseudoaneurysm and hoarseness.
Conclusions:
This clinical vignette highlights the potential of balloon catheter-assisted percutaneous ultrasound-guided thrombin injection as an alternative to open or endovascular repair of pseudoaneurysms of the subclavian arteries.