Related Experiment Video
Updated: Mar 3, 2026

TAPE: A Biodegradable Hemostatic Glue Inspired by a Ubiquitous Compound in Plants for Surgical Application
Published on: June 8, 2016
Mitral Valve Necrosis After Cardiac Surgery Using Gelatin-Resorcinol-Formaldehyde Glue
Yuki Tanaka1, Tadashi Kitamura1, Yurie Miyata1
1Department of Cardiovascular Surgery, Kitasato University School of Medicine, Sagamihara, Japan.
Abstract:
We present a rare case of mitral regurgitation with anterior mitral leaflet perforation associated with gelatin-resorcinol-formaldehyde (GRF) glue. We performed mitral valve replacement for anterior mitral leaflet perforation occurred 7 years after aortic valve replacement and abscess cavity repair using GRF glue. Long-term follow-up is needed for patients who have undergone surgeries using GRF glue or BioGlue (CryoLife, Inc, Kennesaw, GA) because of the possibility of late complications. In particular, when an eccentric mitral regurgitation is observed after aortic root surgery using GRF glue or BioGlue, anterior mitral leaflet perforation should be considered.