Shifting the paradigm in gas chromatography mass spectrometry pesticide analysis using high resolution accurate mass
1Agrifood Campus of International Excellence (ceiA3), Department of Chemistry and Physics, University of Almeria, European Union Reference Laboratory for Pesticide Residues in Fruit and Vegetables, 04120 Almería, Spain.
Abstract:
In the last 10 years, the majority of the pesticide food control laboratories moved from GC-MS to GC-MS/MS as the preferred analytical technique to address GC amenable compounds. The main reason for this change was the negative impact on the single stage GC-MS analysis caused by the interference from coeluting matrix compounds. The new development of gas chromatography coupled to high resolution accurate mass spectrometry (GC-HRAMS) provides opportunities to overcome such matrix interferences as a result of its much higher selectivity; allowing laboratories to carry out full-scan analysis covering the most exigent analytical performance criteria. The aim of this work is the evaluation of the main analytical performance parameters for the multiresidue screening of pesticide residues by a gas chromatography-Orbitrap™ mass spectrometer in fruits and vegetables. Electron ionization and full-scan high resolution mass spectrometry was selected for this evaluation. Mass resolving power, selectivity, sensitivity, analyte identification and database generation are discussed in light of the analysis of various commodities and a large scope of pesticides. The selected operational conditions provided optimal mass accuracy, within ±1mDa and achieved LOQs of 10μg/kg or lower for practically all the selected pesticides and commodities. Applicability for quantitative residue analysis was verified by the validation of the 210 pesticides in four matrices (tomato, apple, leek and orange). The performance of the GC-EI-full scan Orbitrap HRAMS developed method was confirmed with the analysis of 102 real samples providing good results.
More Related Videos
11:00Untargeted Metabolomics from Biological Sources Using Ultraperformance Liquid Chromatography-High Resolution Mass Spectrometry UPLC-HRMS
Published on: May 20, 2013
11:14Rapid High-throughput Species Identification of Botanical Material Using Direct Analysis in Real Time High Resolution Mass Spectrometry
Published on: October 2, 2016
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
High-Resolution Mass Spectrometry (HRMS)
Gas Chromatography: Types of Detectors-II
High-Performance Liquid Chromatography: Types of Detectors
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...