Related Experiment Video
Updated: Mar 3, 2026

Author Spotlight: Demonstrating Systematic Endobronchial Ultrasound to New Endoscopists
Published on: August 11, 2023
Factors affecting patients' comfort during fiberoptic bronchoscopy and endobronchial ultrasound
Fatma Yıldırım1, Şevket Özkaya2, Ahmet Selim Yurdakul1
1Department of Pulmonary Medicine, Faculty of Medicine, Gazi University, Ankara, Turkey.
Objective:
This study investigated the factors that can affect the comfort of patients who underwent diagnostic fiberoptic bronchoscopy (FOB) and diagnostic endobronchial ultrasonography (EBUS) for the first time and the effect of the patients' anxiety level on their comfort during the procedure.
Materials And Methods:
We recorded the demographics of the patients, the medications they used previously, the anesthesia applied during the procedure, the experience of the operator, the insertion technique of the bronchoscope, the types of the bronchoscopic interventions during the procedure, the duration of the procedure, and the anxiety levels of the patients before the session. Patients' discomfort level before and after the procedure and anxiety levels before the procedure were evaluated using a visual analog scale (VAS), and willingness for repeating FOB and EBUS was assessed using a questionnaire.
Results:
We found that longer examination time, higher anxiety level before the procedure, the nasal insertion of bronchoscope, and higher number of interventions are related to the increased discomfort during FOB and EBUS. Patients' willingness for repeating FOB and EBUS increased as the level of discomfort decreased during the procedure.
Conclusion:
The patient's anxiety level should be determined using a questionnaire before the FOB and EBUS procedures, and the operator should adjust their procedure according to the patients' anxiety level.
Related Concept Videos
Endoscopic Studies I: Bronchoscopy and Thoracoscopy
Bronchoscopy
Description
Bronchoscopy is a procedure that involves direct visualization of the larynx, trachea, and bronchi for diagnostic and therapeutic purposes. A flexible fiber optic or rigid bronchoscope is used to carry out the procedure. The fiber-optic bronchoscope is more frequently used due...
Ultrasound II: Endoscopic Ultrasound and FibroScan
Endoscopic Ultrasound (EUS):
Endotracheal Intubation I: Procedure
The ET tube comprises various components, including a standard adaptor to attach a bag-valve-mask (BVM) or ventilator, a cuff, a pilot balloon, and radiopaque markings along its length to measure the insertion distance. The tube sizes...
Endoscopic Studies II: Thoracocentesis
Description
Excess pleural fluid or air may accumulate in some respiratory disorders in the thoracic cavity. To treat pleural effusion, a physician conducts thoracentesis by carefully piercing the chest wall and entering...
Factors Affecting Pulmonary Ventilation
Alveolar Surface Tension
The alveolar fluid lines the luminal surface of the alveoli and exerts a force called surface tension. This force is caused by the polar water molecules in the liquid being more strongly attracted to each...
Endoscopic Procedures I: Esophagogastroduodenoscopy
During an EGD, the endoscope can be used to:

